Страница 2: ... your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if n...

Страница 3: ...ting 19 4 2 4 Alert Trap 20 4 2 5 Factory Default 21 4 2 6 Firmware Update 22 4 2 7 Reboot 25 4 3 PORT MANAGEMENT 26 4 3 1 Port Configuration 27 4 3 2 Port Mirroring 29 4 3 3 Bandwidth Control 30 4 3 4 Broadcast Storm Control 31 4 3 5 Port Statistics 32 4 4 VLAN SETTING 33 4 4 1 802 1Q VLAN 36 4 4 2 Port Based VLAN 45 4 4 3 MTU VLAN 47 4 5 TRUNK SETTING 48 4 6 QOS SETTING 50 4 6 1 Priority Mode 51...

Страница 4: ... POE PROVISION PROCESS 66 7 1 LINE DETECTION 66 7 2 CLASSIFICATION 66 7 3 START UP 67 7 4 OPERATION 67 7 5 POWER DISCONNECTION SCENARIOS 67 8 TROUBLESHOOTING 68 APPENDIX A NETWORKING CONNECTION 69 A 1 SWITCH S RJ 45 PIN ASSIGNMENTS 69 A 2 RJ 45 CABLE PIN ASSIGNMENT 69 ...

Страница 5: ...ctive and highly reliable network connection for data as well as power Furthermore it is the ideal device for bridging among Ethernet Fast Ethernet workgroups and networks The Web Smart PoE Switch equipped with non blocking 3 2 7 2Gbps backplane greatly simplifies the tasks of upgrading your LAN for catering to increase bandwidth demands For efficient management the Web Smart PoE Switch is equippe...

Страница 6: ... 18 port based VLAN groups 32 IEEE 802 1Q VLAN groups MTU VLAN Supports up to 2 Trunk groups each trunk for up to maximum 4 port with 800Mbps bandwidth Supports QoS bandwidth control and MAC address filter TCP UDP filter on each port Supports port mirroring function and IGMP Snooping v1 v2 PoE power Disable Enable and PoE power consumption monitoring by management interface Firmware upgrade throug...

Страница 7: ...Mbps 16Mbps 32Mbps 64Mbps Broadcast Storm Control Yes 5 10 25 50 Disable Port Statistics Display each port s detail Ethernet traffic counter information VLAN 16 18 port based VLAN groups 32 IEEE 802 1Q VLAN groups MTU VLAN Port trunking Support 2 groups of 4 Port trunk support up to 800Mbps bandwidth per trunk Port Mirroring Port mirroring allows monitoring of the traffic across any port in real t...

Страница 8: ...r Function PWR Green Lights to indicate that the Switch has power Per 10 100Mbps port LED Color Function PoE In use Orange Lights to indicate the port is providing 48VDC in line power 1 8 ports LNK ACT Green Lights to indicate the link through that port is established at 10 100Mbps full duplex mode Blink slowly to indicate the link through that port is established at 10 100Mbps half duplex mode Bl...

Страница 9: ...rt PoE Switch on a desktop or shelf simply completed the following steps Step 1 Attached the rubber feet to the recessed areas on the bottom of the Web Smart PoE Switch Step 2 Place the Web Smart PoE Switch on a desktop or shelf near an AC power source Step 3 Keep enough ventilation space between the Web Smart PoE Switch and the surrounding objects Notice When choosing a location please keep in mi...

Страница 10: ... brackets to the Web Smart PoE Switch Caution You must use the screws supplied with the mounting brackets Damage caused to the parts by using incorrect screws would invalidate your warranty Step 3 Secure the brackets tightly Step 4 Follow the same steps to attach the second bracket to the opposite side Step 5 After the brackets are attached to the Web Smart PoE Switch use suitable screws to secure...

Страница 11: ...e You can manage the Switch remotely by having a remote host with Web browser such as Microsoft Internet Explorer Netscape Navigator or Mozilla Firefox The following shows how to startup the Web Management of the Switch please note the Web Smart PoE Switch is con figured through an Ethernet connection make sure the manager PC must be set on the same IP subnet address for example the default IP add...

Страница 12: ...Discovery Utility from user s manual CD ROM is an ideal solution The following install instructions guiding you for run the Planet Smart Discovery Utility 1 Deposit the Planet Smart Discovery Utility in administrator PC 2 Run this utility and the following screen appears Figure 3 1 Planet Smart Discovery Utility Screen Notice If there are two LAN cards or above in the same administrator PC choose ...

Страница 13: ... in Option tools bar 6 To click the Control Packet Force Broadcast function it can allow assign new setting value to the Web Smart PoE Switch under different IP subnet address 7 Press Connect to Device button then the Web login screen appears in Figure 3 3 8 Press Exit button to shutdown the planet Smart Discovery Utility 3 3 Logging on to the FNSW 1608PS FGSW 1828PS When you log on to the Web Sma...

Страница 14: ...base on the console screens of FGSW 1828PS for FNSW 1608PS the display will be the same to FGSW 1828PS 4 1 Login in to the Switch To access the Web browser interface you must first enter the user name and password the default user name and password is admin You will see the following screen comes out on the Web browser program Figure 4 1 Web Login Screen After the User name and Password is entered...

Страница 15: ... of Web Smart PoE Switch Explained in section 4 4 Trunk Setting Provide Trunk Setting configuration Web Smart PoE Switch Explained in section 4 5 QoS Setting Provide QoS Setting configuration of Web Smart PoE Switch Explained in section 4 6 Security Provide Security configuration of Web Smart PoE Switch Explained in section 4 7 Misc Operation Provide Misc Operation configuration of Web Smart PoE S...

Страница 16: ...tware Version Device Description Ex plained in section 4 2 1 IP Configuration Allow to change the IP subnet address of Web Smart PoE Switch Explained in section 4 2 2 Password Setting Allow to change the username and password of Web Smart PoE Switch Explained in section 4 2 3 Alert Trap Allow configure the Alert Trap function of Web Smart PoE Switch Explained in section 4 2 4 Factory Default Allow...

Страница 17: ...dware Version Software Version and System Up Time also allow define the device description and press Apply button to take affect The screen in Figure 4 4 appears Figure 4 4 System Information Web Page Screen Notice Up to 16 characters is allowed for the Device Description ...

Страница 18: ...Configuration Web Page Screen After setup complete and press Apply button to take affect The following screen in Figure 4 6 appears and then another Web page login screen with new IP address will show up After input correct username and password then can continue the Web Smart PoE Switch management Figure 4 6 IP Configuration Web Page Screen ...

Страница 19: ...ord Setting This section provides change the Username and Password the screen in Figure 4 7 appears Figure 4 7 Password Setting Web Page Screen Notice Up to 8 characters is allowed for the username and password assign ...

Страница 20: ...Alert IP Address Allow assign an Alert IP Address of one specific workstation that gets SNMP Trap Trap Event Cold start Choose this event then can get Cold Start Trap Login Fail Choose this event then can get Login Fail Trap Password Changed Choose this event then can get Password Changed Trap IP Changed Choose this event then can get IP address Changed Trap PoE Alert Choose this event then can ge...

Страница 21: ...ure 4 9 Factory Default Web Page Screen Press Factory Default button to take affect The following screen in Figure 4 10 appears and then another Web page login screen with default setting will show up After input default username and password then can continue the Web Smart PoE Switch management Figure 4 10 Factory Default Web Page Screen ...

Страница 22: ... upgrade of the Web Smart PoE Switch the screen in Figure 4 11 appears Figure 4 11 Firmware Update Web Page Screen ress Update button for start the firmware upgrade process the screen in Figure 4 12 4 13 appears P Figure 4 12 Firmware Update Web Page Screen ...

Страница 23: ...13 Firmware Update Web page Screen Then the following screen appears on administrator PC the screen in Figure 4 14 appears press Browser button to find the firmware locati Figure 4 14 Firmware Update Web Page Screen ...

Страница 24: ...e W se wait for a while for system reboot screen in Figure 4 15 appears Figure 4 15 Firmware Update Web Page Screen hen firmware upgrade process is completed then the following screen appears plea After device reboot then can use the latest firmware of the Web Smart PoE Switch Figure 4 16 Firmware Update Web Page Screen ...

Страница 25: ... the Web Smart PoE Switch the screen in Figure 4 17 appears This section allow Figure 4 17 Reboot Web Page Screen ress Reboot button to reboot the Web Smart PoE Switch the screen in Figure 4 18 appears After device reboot P completed the Web login screen appears and login for further management ...

Страница 26: ...ent Web Page Screen Objects Object Description Port Configuration Allow to configure each port of Web Smart PoE Switch Explained in section 4 3 1 Port Mirroring Allow to use port mirroring function of Web Smart PoE Switch Explained in section 4 3 2 Bandwidth Control Allow to configure bandwidth control of each port from Web Smart PoE Switch Explained in section 4 3 3 Broadcast Storm Control Allow ...

Страница 27: ...4 5 n objects of Web Smart PoE Switch 1 Port Conf s section introduces d ettings of per port on Web Smart PoE Switch the screen in Figure 4 20 4 21 appears and e Port Configuratio descriptions th Figure 4 20 Port Configuration Web Page Screen ...

Страница 28: ...available options are Enable and Disable Default mode is Enable Port Description Allow input per Port Description of Web Smart PoE Switch up to maximum 8 characters allow Apply button Press Apply button for save current configuration of each port on Web Smart PoE Switch Object Description Port Indicate port 1 to port 16 FNSW 1608PS port 1 to port 18 FGSW 1828PS Current Status d Mode and Flow Contr...

Страница 29: ...ing Web Page Screen Object Description Monitored Packets Provide disable and enable the Port Mirroring function the available options are Disable RX TX TX RX Default mode is Disable Destination Port The destination port can be used to see all monitor port traffic It can connect destination port to LAN analyzer or Netxray Source Port The source port that want to monitor All monitor port traffic wil...

Страница 30: ...reen Objects Object Description Port Indicate port 1 to port 16 of Web Smart PoE Switch Tx Rate Provide No Limit 1Mbps 2Mbps 4Mbps 8Mbps 16Mbps 32Mbps 64Mbps different transmit rate for bandwidth control function of Web Smart PoE Switch Default mode is No Limit Rx Rate Provide No Limit 1Mbps 2Mbps 4Mbps 8Mbps 16Mbps 32Mbps 64Mbps different re ceive rate for bandwidth control function of Web Smart ...

Страница 31: ...descriptions the Broadcast Storm Control objects of Web Smart PoE Switch Figure 4 24 Broadcast Storm Control Web Page Screen Table 4 8 Descriptions of the Broadcast Storm Control Screen Objects Object Description Filter Mode 5 10 25 50 Disable different filter mode Default mode is Disable Provide Apply button Press this button for save current configuration of Web Smart PoE Switch ...

Страница 32: ...of Ethernet traffic counter mode the available options are shown as below Receive Packet Transmit Packet collision Count Transmit Packet Drop Packet Receive Packet CRC error Packet Receive Packet Default mode is Receive Packet Transmit Packet Port Indicate port 1 to port 16 FNSW 1608PS port 1 to port 18 FGSW 1828PS Transmit Display Transmit count value from each port Receive Display Receive count ...

Страница 33: ...an also provide a level of security to you ackets between stations at are members of the VLAN Any port can be configured as either tagging or untagging The untagging feature of IEEE 802 1Q VLAN allows VLAN to work with legacy switches that don t recognize VLAN tags in packet headers The tagging feature allow 802 1Q compliant sw single physical connection and allows Span nin enabled on all ports an...

Страница 34: ...witch has memory in its VLAN table to store them may be tag unaware a decision must be made at each port on a tag aware device before packets are transmitted should the packet to be transmitted have a tag or not If the transmitting port is connected to a tag unaware device the packet should be untagged If the transmitting port is connected to a tag aware device the packet should be tagged Default ...

Страница 35: ...Page Screen Table 4 10 Descriptions of the VLAN Setting Screen Objects Object Description VLAN Mode Provide different VLAN operation mode the available options are shown as below No VLAN 802 1Q VLAN Explained in section 4 4 1 Port Based VLAN Explained in section 4 4 2 MTU Explained in section 4 4 3 Default mode is No VLAN Apply button Press this button for save current configuration of Web Smart P...

Страница 36: ...rom VLAN from the VLAN Mode and press Apply button to enable the 802 1Q VLAN function The screen in Figure 4 27 4 28 appears and table 4 11 description the 802 1Q VLAN objects of Web Smart PoE Switch 4 1 802 1Q VLAN Figure 4 27 802 1Q VLAN Configuration Web Page Screen 802 1Q VLAN Configuration Web Page Screen Figure 4 28 ...

Страница 37: ...rt as member port from different 802 1Q VLAN groups Apply button Press this button for save current configuration of Web Smart PoE Switch Per Port Setting Allow to define per port UnTag Tag Uplink and PVID The screen in Figure 4 29 appears Delete Group Press this button for delete existence 802 1Q VLAN groups Add New Group Press this button for create a new 802 1Q VLAN groups Up to maximum 32 802 ...

Страница 38: ...PC 5 and PC 6 received no packet 3 While the packet leaves Port 2 it will be stripped away it tag becoming an untagged packet 4 While the pack PC 1 and PC 2 will received the ket through Port 1 and Port 2 6 While the pa d packet While PC 4 d PC 6 will r ile the pa cket a ket with VLAN Tag 3 Notice fic flow et leaves Port 3 it will keep as a tagged packet with VLAN Tag 2 Tagged packet entering VLAN...

Страница 39: ... 39 Setup steps 1 Create VLAN Group Set VLAN Group 1 default VLAN with VID VLAN ID 1 Add two VLANs VLAN 2 and VLAN 3 VLAN Group 2 with VID 2 VLAN Group 3 with VID 3 Figure 4 31 Add new VLAN Group Screen ...

Страница 40: ...her ports Port 7 Port 18 Figure 4 32 Assign VLAN members for VLAN 2 and VLAN 3 Please remember to remove the Port 1 Port 6 from VLAN 1 membership since the Port 1 Port 6 had been assigned to VLAN 2 and VLAN 3 Figure 4 33 Remove specify orts from VLAN 1 member p 2 Assign VLAN Member ...

Страница 41: ...e overlap 3 Assign PVID for each port Port 1 Port 2 and Port 3 PVID 2 Port 4 Port 5 and Port 6 PVID 3 Port 7 Port 18 PVID 1 4 Enable VLAN Tag for specific ports Link Type Port 3 VLAN 2 and Port 6 VLAN 3 The Per Port VLAN configuration in Figure 4 34 appears Figure 4 34 Port 1 Port 6 802 1Q VLAN Configuration ...

Страница 42: ...ccess one public server 802 1Q VLAN with overlapping area scenario he two separa Figure 4 35 A Server connect to the VLAN overlapping area 1 Specify Port 7 on the Web Smart PoE Switch that connects to the server 2 Assign Port 7 to both VLAN 2 and VLAN 3 at the VLAN Member configuration page The screen in Figure 4 36 appears Figure 4 36 VLAN overlap port setting ...

Страница 43: ...as a Public Area that overlapping with both VLAN 2 members and VLAN 3 members Figure 4 37 VLAN 1 The public area member assign 4 Setup Port 7 with PVID 1 at VLAN per Port Configuration page The screen in Figure 4 38 appears ...

Страница 44: ...ort 7 with PVID 1 rt 3 and VLAN 3 members Port 4 to Port Although the VLAN 2 members Port 1 to Po 6 also belongs to VLAN 1 But with different PVID settings packets form VLAN 2 or VLAN 3 is not able to access to the other VLAN ...

Страница 45: ...Based VLAN from VLAN from the VLAN Mode and press Apply button to enable the port based VLAN function The screen in Figure 4 39 4 40 appears and table 4 14 description the Port Based VLAN objects of Web Smart PoE Switch Figure 4 39 Port Based VLAN Configuration Web Page Screen Figure 4 40 Port Based VLAN Configuration Web Page Screen ...

Страница 46: ...l can access port 18 due to port 18 is using overlapping feature to communicate with port 1 to port 17 17 is being separated physically due to it belongs to different VLA V Object Description VID Display different VLAN ID from multi port based VLAN groups VLAN Name Assign and display different VLAN name from multi port based VLAN groups Up to maximum 8 characters allow Port Indicate port 1 to port...

Страница 47: ...press Apply button to enable the MTU VLAN function U VLAN objects of Web Smart PoE Switch Figure 4 41 MTU VLAN Configuration Web Page Screen Table 4 15 Descriptions of the MTU VLAN Setting Screen Objects Object Description MTU Port Indicate the MTU Port of Web Smart PoE Switch Member Port Indicate the Member Port of Web Smart PoE Switch Apply button Press this button for save current configuration...

Страница 48: ...ink aggregation prior to connecting any cable between the switches to avoid creating a data loop Disconnect all link aggregation port cables or disable the link aggregation ports before removing a port link aggre gation to avoid creating a data loop It allows a maximum of 4 ports to be aggregated at the same time and up to 2 groups If the group is defined as a local static link aggregation group t...

Страница 49: ...witch Figure 4 42 Trunk Setting Web Page Screen Table 4 16 Descriptions of the Trunk Setting Screen Objects Object Description Trunk Hash Algorithm selection Provide four various Trunk Hash Algorithm polices the available options are shown as below SA DA Default Port ID SA DA Default mode is SA DA Trunk1 Indicate the Trunk Member Port 1 2 3 4 of Web Smart PoE Switch Trunk2 Indicate the Trunk Membe...

Страница 50: ...r business critical applications Applying security policy through traffic filtering Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by minimizing delay and jitter Improve performance for specific types of traffic and preserve performance as the amount of traffic grows Reduce the need to constantly add bandwidth to the network Manage network co...

Страница 51: ... Mode Web Page Screen Table 4 18 Descriptions of the Priority Mode Screen Objects Object Description Priority Mode Provide three different Priority polices on Web Smart PoE Switch the available options are shown as below Fist In First Out All High Before Low Weight Round Robin Low weight 0 7 range High weight 0 7 range Default mode is First In First Out Apply Press this button for save current con...

Страница 52: ...f the Class of Service Configuration Screen Objects Object Description Enable High Priority enable the High Priority function Default mode is Enable Allow to disable or Port Indicate port 1 to port 16 FNSW 1608PS port 1 to port 18 FGSW 1828PS Port Base y based on Port Base policy Define per port Class of Service polic VLAN Tag Define per port Class of Service policy based on VLAN Tag priority poli...

Страница 53: ...S Configuration of Web Smart PoE Switch the screen in Figure 4 46 4 47 appears and table 4 20 descriptions the TCP UDP Port Based QoS Configuration of Web Smart PoE Switch Figure 4 46 TCP UDP Port Based QoS Configuration Web Page Screen Figure 4 47 TCP UDP Port Based QoS Configuration Web Page Screen ...

Страница 54: ...PS 443 Provide F I F O Discard Low High options MSN 1863 Provide F I F O Discard Low High options XRD_RDP 3389 Provide F I F O Discard Low High options QQ 4000 8000 Provide F I F O Discard Low High options ICQ 5190 Provide F I F O Discard Low High options Yahoo 5050 Provide F I F O Discard Low High options BOOTP_DHCP 67 68 Provide Low High options User_Define_a Provide F I F O Discard Low High opt...

Страница 55: ...b Smart PoE Switch Figure 4 48 Security Filter Web Page Screen eb Page Screen Objects Table 4 21 Descriptions of the Security Filter W Object Description MAC Address Filter Web Smart PoE Switch Explained in section Allow define three MAC Address on per port of 4 7 1 TCP UDP Filter Allow define the filter policy of TCP UDP flow on Web Smart PoE Switch Explained in section 4 7 2 ...

Страница 56: ... of Web Smart PoE Switch Select Port Allow to select port 1 to port 16 FNSW 1608PS port 1 to port 18 FGSW 1828PS Binding Allow to itch Disable or Enable the binding function on each port of Web Smart PoE Sw Apply Press this button for save current configuration of Web Smart PoE Switch Object Description Port Indicate port 1 to port 16 FNSW 1608PS port 1 to port 18 FGSW 1828PS Binding Status Displa...

Страница 57: ...on introduces detail information of TCP UDP Filter of Web Smart PoE Switch the screen in Figure 4 50 appea and table 4 24 descriptions the TCP UDP Filter Configuration of Web Smart PoE Switch rs Figure 4 50 TCP UDP Filter Web Page Screen ...

Страница 58: ... TCP UDP Filter policy FTP 20 21 SSH 22 TELNET 23 SMTP 25 DNS 53 TFTP 69 HTTP 80 8080 POP3 110 NEWS 119 SNTP 123 NetBIOS 137 139 IMAP 143 220 SNMP 161 162 HTTPS 443 MSN 1863 XRD_RDP 3389 QQ 4000 8000 ICQ 5190 Yahoo 5050 BOOTP_DHCP 67 68 User_Define_a User_Define_b User_Define_c User_Define_d Allow to choose list protocol for filtering Secure Egress Port Indicate port 1 to port 16 FNSW 1608PS port ...

Страница 59: ...bject Description Output Queue Aging Time Allow define the Output Queue Aging Time of Web Smart PoE Switch the available op tions are Disable 200ms 400ms 600ms and 800ms Default mode is Disable VLAN Striding Allow Disable or Enable the VLAN Striding function of Web Smart PoE Switch Default mode is Disable IGMP Snooping V1 V2 Allow Disable or Enable the IGMP Snooping V1 V2 function of Web Smart PoE...

Страница 60: ...nsumption is monitored by measuring voltage and current The input power consumption is equal to the system s aggregated power consumption The power management concept allows all ports to be active and acti vates additional ports as long as the aggregated power of the system is lower than the power level at which additional PDs cannot be connected When this value is exceeded ports will be deactivat...

Страница 61: ... priority value range from 1 4 and the High priority is 1 Device class Class 0 is the default for PDs However to improve power management at the PSE the PD may The PD is classified based on power The classification of the PD is the maximum power that the PD will draw across all input voltages and operational modes A PD shall return Class 0 to 3 in accordance with the maximum power draw as specifie...

Страница 62: ...ase re login the Web Smart PoE Sw This section provide logout function on Web Smart PoE Switch after choose this function and the fol Please press Logout button to take effect and Login W itch for further management Figure 4 53 Logout Web Page Screen Figure 4 54 Login Web Page Screen ...

Страница 63: ...error checking before transmission Therefore no error packets occurrence it is the best choice when a network needs efficiency and stability The Ethernet Switch scans the destination address from the packet header searches the routing table provided for the incoming port and forwards the packet only if required The fast forwarding makes the switch attractive for connecting servers directly to the ...

Страница 64: ...e operation of each end device to be ed by data cables rather than by separate power cords New network applications such as IP Cameras VoIP Phones o IEEE802 3af also c dard to define the transmission for power over Ethernet The 802 3af is delivering 48V power over RJ 45 wiring Be s 802 3af also define two types of source equipment Mid Span and End Span Mid Span Mid Span device is placed betwee and...

Страница 65: ...moves into new offices next month The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work power to the outside is not affordable References IEEE Std 802 3af 2003 Amendment to IEEE Std 802 3 2002 including IEEE Std 802 3ae 2002 2003 Page s 0_1 121 White Paper on Power over Ethernet IEEE802 3af http www poweroverethernet com articles p...

Страница 66: ...20 5 12 5 25 0 Startup Where the powered device will startup 42 38 Normal operation Supply power to device 36 57 25 0 60 0 7 1 Line Detection Before power is applied safety dictates that it must first be ensured that a valid PD is connected to the PSE s output This and involves the PSE seeking a specific 25 KΩ signature resistor Detection of is signature indicates that a valid PD is connected and ...

Страница 67: ...rise in voltage reaching hig lines Once provision of power is initiated it is common for inrush current to be experienced at the PSE port due to the PD s input capacitance A PD must be designed to cease inrush current consumption of over 350 mA within 50 ms of power provi sion startup 7 4 Operation D Power Overloads overload a PD wing a higher ower lev wed 12 95 his period to pr t the cabling fras...

Страница 68: ...ical or software switch to modes Auto negotiation may not recognize this type of full duplex setting Why the Switch doesn t connect to the network Solution Check the LNK ACT LED on the switch Try another port on the Switch Make sure the cable is installed properly Mak sure the cable is the right type Turn off the power After a while turn on power again e Why I connect my PoE device to FNSW 1608PS ...

Страница 69: ...DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive Tx transmit 4 5 Not used 6 Rx receive Tx transmit 7 8 Not used A 2 RJ 45 cable pin assignment 21 3 6 1 2 3 6 21 3 6 The standard RJ 45 receptacle connector ...

Страница 70: ...hite Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Straight Cable SIDE 1 SIDE2 SIDE 1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SIDE 2 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown 1 White Orange 2 Green 3 White Orange 4 Blue 5 White Blue 6 Orange 7 White Brown 8 Brown A 1 Stra nd Crossover Cable Please make sure your connected cabl...

Страница 71: ...lowing standards were applied Emission EN 50081 1 1992 Conducted Radiated EN 55022 1998 Harmonic EN 61000 3 2 1995 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 1995 RS EN 61000 4 3 1996 EFT Burst EN 61000 4 4 1995 Surge EN 61000 4 5 1995 CS EN 61000 4 6 1996 Voltage Disp EN 61000 4 11 1994 Responsible for marking this declaration if the Manufacturer Authorized representative e...

Страница 72: ...y Directive on 89 336 EEC 92 31 EEC 93 68 EEC For the evaluation regarding the EMC the following standards were applied Emission EN 55022 1998 Class B Harmonic EN 61000 3 2 2000 Flicker EN 61000 3 3 1995 Immunity EN 55024 1998 ESD EN 61000 4 2 1995 RS EN 61000 4 3 1995 EFT Burst EN 61000 4 4 1995 Surge EN 61000 4 5 1995 CS EN 61000 4 6 1996 Magnetic Field EN 61000 4 8 1993 Voltage Disp EN 61000 4 ...