User’s Manual of SGSD-1022 / SGSD-1022P
SGSW-2840 / SGSW-2840P
401
Console(config)#sntp poll 60
Console(config)#
Related Commands
sntp client
show sntp
This command displays the current time and configuration settings for the SNTP client, and indicates whether or not the local
time has been properly updated.
Command Mode
Normal Exec, Privileged Exec
Command Usage
This command displays the current time, the poll interval used for sending time synchronization requests, and the current
SNTP mode (i.e., unicast).
Example
Console#show sntp
Current time: Dec 23 05:13:28 2002
Poll interval: 16
Current mode: unicast
SNTP status : Enabled
SNTP server 137.92.140.80 0.0.0.0 0.0.0.0
Current server: 137.92.140.80
Console#
clock timezone
This command sets the time zone for the switch’s internal clock.
Syntax
clock timezone name hour hours minute minutes {before-utc | after-utc}
name - Name of timezone, usually an acronym. (Range: 1-29 characters)
hours - Number of hours before/after UTC. (Range: 0-13 hours)
minutes - Number of minutes before/after UTC. (Range: 0-59 minutes)
before-utc - Sets the local time zone before (east) of UTC.
after-utc - Sets the local time zone after (west) of UTC.
Default Setting
None
Содержание SGSD-1022
Страница 112: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 112 Figure 4 3 14 SNMPv3 View Edit page screenshot ...
Страница 121: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 121 Figure 4 4 7 Mirror Port Configuration page screenshot ...
Страница 278: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 278 Figure 4 11 18 Settings screenshot ...
Страница 313: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 313 Figure 4 11 39 Settings screenshot ...
Страница 315: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 315 Figure 4 11 41 Settings screenshot ...
Страница 561: ...User s Manual of SGSD 1022 SGSD 1022P SGSW 2840 SGSW 2840P 561 0 1 3 4094 1 2 Console ...