58-346
Function:
Configure the analyzer used by sFlow, the no command deletes the analyzer.
Parameter:
sflowtrend
is the analyzer of Inmon.
Command Mode:
Global Mode
Default:
Do not configure
Usage Guide:
Configure this command when using sFlowTrend.
Example:
Switch(config)#sflow analyzer sflowtrend
58.3 sflow counter-interval
Command:
sflow counter-interval
<interval-value>
no sflow counter-interval
Function:
Configure the max interval of the sFlow statistic sampling; the “no” form of this command deletes the statistic
sampling interval value.
Parameter:
<interval-value>
is the value of the interval with a valid range of 20~120 and shown in second.
Command Mode:
Port Mode
Default:
No default value