1

 

Overview 

Planck Vision Systems' dual-vision thermal network camera (TNC Series) can simultaneously record visible and 
thermal images while collecting characteristic temperature information from the scene. It can be used in indoor 
and outdoor environments for asset monitoring, intelligent security, and other applications. Through an IP 
network, the TNC Series transmits collected data to PC clients or web browsers (Chrome) for real time surveillance 
and alarm condition monitoring. SDK development kits are available to facilitate secondary development and 
integration of Planck Vision Systems cameras with third-party platforms. The TNC series supports RTSP, RTP, TCP, 
UDP, ONVIF and other general protocols, such as MODBUS to upload data to the client platform. 

2

 

Camera Specifications 

Table 3-1 provides a list of features that are common to all cameras in the TNC Series. Planck Vision systems

 

TNC10 cameras are an economical choice for a wide range of applications.  The TNC200 cameras are built to 
customers specifications. 

Table 2-1: Common features

*

 of the TNC Series 

Network

 

Network Protocol

 

ICMP, TCP, UDP, RTP, RTSP, DHCP, PPPOE, UPNP, 

DDNS, ONVIF, 802.1x, FTP, HTTP

 

User Rights

 

Three levels of user rights

 

Security Measures

 

User authentication (ID and PW)

 

Video Compression

 

H.264/H.265

 

Audio Compression

 

Audio G.711u/Intercom G.722

 

 

Mainstream

 

Visible: 1080p/720P with 30fps. Thermal: 25fps

 

Sub Stream

 

Visible: D1/CIF 30fps can be set. Thermal: 25fps

 

Smart Functions

 

Fire Detection

 

Supported

 

Temperature Measurement

 

4 temperature rule types (above high, below low, in between, 

out of range)

 

Temperature Range

 

Temperature range -20°C to 550°C

 

Temperature Accuracy

 

Temperature accuracy: ±2°C or ±2%, whichever is greater

 

Perimeter Detection

 

Intrusion, line crossing, region entrance, region exiting

 

System Integration

 

Audio Input

 

1 Channel

 

Audio Output

 

1 Channel

 

Communication Interface

 

RJ45 10M/100M self-adaptive; RS485 

 

Alarm Input

 

1 Channel

 

Alarm Output

 

1 Channel

 

Analog Video Output

 

PAL/NTSC/BNC

 

Built-in Onboard Storage

 

Optional

 

 

*

 Specifications are subject to change. 

2.1

 

TNC10 

This camera comes with a 160 x 120 uncooled microbolometer detector, a standard 57 x 48 field of view optics and 
an IP67 rating bullet style housing. 

Содержание TNC Series

Страница 1: ...ions 2 2 1 TNC10 2 2 2 TNC200 3 3 What s in the Box 3 4 TNC Series physical interface 4 5 Initial Setup 5 5 1 User password modification 6 5 2 Device IP modification 6 6 Communication Protocols 7 6 1 RTSP instructions 7 6 2 ONVIF instructions 8 7 Default network settings 10 8 Thank you 10 TNC Series ...

Страница 2: ...C200 cameras are built to customers specifications Table 2 1 Common features of the TNC Series Network Network Protocol ICMP TCP UDP RTP RTSP DHCP PPPOE UPNP DDNS ONVIF 802 1x FTP HTTP User Rights Three levels of user rights Security Measures User authentication ID and PW Video Compression H 264 H 265 Audio Compression Audio G 711u Intercom G 722 Mainstream Visible 1080p 720P with 30fps Thermal 25...

Страница 3: ... 120 380 384 x 288 640 640 x 512 HV is the horizontal field of view For example 57 means a 57 HVOF BT is the camera body type includes IP other BU is bullet PP is Planck Pro body IO interface options Standard options include FF full feature IP internet and power only 3 What s in the Box Table 3 1 Packing list Serial number name quantity 1 Camera 1 2 Power Adapter 1 3 Mounting screws 4 4 Expansion ...

Страница 4: ...ight mode detection 4 IR Illuminator 30 meters illumination for visible camera 5 Network Interface LAN Connect standard Ethernet cable 6 Power connector DC 12V Input DC 12V power supply 7 RS485 serial port RS485 RS485 8 Audio input AUDIO IN Input audio signal receives analog audio signal from pickups and other equipment 9 Audio output AUDIO OUT Output audio signal to speakers and other equipment 1...

Страница 5: ...ace for the first time use the camera s default IP address Step 3 When connecting to the camera for the first time enter the default user name 888888 and password 888888 and click OK Figure 5 1 Step 4 The first time the Web Interface is used the video preview may not work To remedy download and install the required video file from the link provided in the header bar of the web interface Step 5 The...

Страница 6: ...r Management tab as shown in Figure 5 3 Click OK to save any changes Figure 5 3 User Password management interface 5 2 Device IP modification To change the camera IP address select the Setting tab Network tab and IP Address Port tab as shown in Figure 5 4 Click OK to save changes Restart the device for the new IP address to take effect Figure 5 4 IP address and port interface ...

Страница 7: ...C10 streams Visible main stream rtsp 192 168 1 19 354 0 888888 888888 main Visible sub stream rtsp 192 168 1 19 354 0 888888 888888 sub Thermal main stream rtsp 192 168 1 19 354 1 888888 888888 main Thermal sub stream rtsp 192 168 1 19 354 1 888888 888888 sub TNC200 streams Visible main stream rtsp 192 168 1 19 554 0 888888 888888 main Visible sub stream rtsp 192 168 1 19 554 0 888888 888888 sub T...

Страница 8: ...owing steps are taken for this test 1 Install and run the onvif device manager odm v2 2 250 2 The camera should automatically appear in the Device list Figure 6 2 3 Enter the login user name admin and password of your camera and click Log in 4 Select your IP Camera then click Live video under NVT corresponding to the visible V_SRC_000 or the thermal V_SRC_001 video stream Figure 6 3 Figure 6 2 Log...

Страница 9: ...TNC Series User Manual v1 4 www planckvisionsystems com 9 Figure 6 3 Live video from ONVIF Device Manager ...

Страница 10: ...ticast port 6500 RTSP 354 554 ONVIF 8000 Table 7 2 Default user settings User Name Password Administrator 888888 888888 Advanced 666666 666666 Ordinary 333333 333333 8 Thank you Thank you for purchasing a Planck Vision Systems TNC series product We develop our products to deliver reliable long lasting performance and want to make sure you are satisfied with your purchase For more product informati...

Отзывы: