2.6.1 Connection diagram
Voltage heating elements
220 -
240 V.
Any kind of connection: the
safety wire must be
connected to the
E
terminal.
Recommended
type of
connection
lead.
1
For 220 - 240 V earthed
one-phase connection.
Bridges connect 1 - 2 - 3
terminals and 4 - 5
terminals.
Protective ground to
H05VV-F3G4
2
For 400 / 220 - 240 V
earthed
two-phase
connection.
Bridges connect 2 - 3
terminals and 4 - 5
terminals.
Protective ground to
H05VV-F4G2,5
3
For 400 / 220 - 240 V
earthed
three-phase
connection.
Bridges connect 4 - 5
terminals, phases in
succession 1, 2 and 3,
Neutral to 4 - 5.
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
E= earth wire
terminal
For the connecting wires, the grounding wire must be longer than the other wires.
Your domestic circuit must be equipped with an automatic circuit breaker.
The appliance must be grounded.
Check that the technical data of your energy supply meet the values on the
nameplate.