J693
29
Communications (continued)
HOST SETTINGS
Settings which affect all communications
with a host.
HOST TIMEOUT
10 SEC (1-60)
The number of seconds a communications
port must be idle before the printer may
process data from a different port. This
value is also used to “timeout” an image /
label download.
CONTROL CODES
♦
Allows the operator to change the prefix
of the commands interpreted by the
printer.
STANDARD CODES
Hex 01 = SOH command; Hex 02 = STX
command; Hex 0D = CR
ALTERNATE CODES
Hex 5E = SOH command; Hex 7E = STX
command; Hex 0D = CR
ALTERNATE CODES 2
Hex 5E = SOH command; Hex 7E = STX
command; Hex 7C = CR
ALTERNATE CODES 3
Hex 5E = SOH command; Hex 23 = STX
command; Hex 0D = CR
FEEDBACK MODE
Returns a Hex 1E, [RS], after each label
successfully prints, and a Hex 1F, [US],
after each batch of labels is printed.
ENABLED
Feedback characters are sent to the host.
DISABLED
No feedback characters are sent.