INSTALLATION & OPERATIONAL SSHLV MANUAL
8
L20-407 rev.5 (06/19)
A
pplic
a
ble
C
ount
rie
s
M
ode
l
Fue
l Ty
pe
G
as
A
pplia
nc
e
C
at
eg
o
ry
G
ro
ss
Input
(
k
W)
N
et
Input
(
k
W)
S
upply
P
ressu
re
(m
b
ar
)
Bu
rn
e
r
P
ressu
re
(m
ab
r)
B
ur
ne
r
O
rif
ic
e
P
ilot
O
ri
fi
ce
(co
d
e)
G
ov
e
rnor
N
om
ina
l G
a
s
R
at
e (
m
3/
h
r)
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
I
2H
LU
I
2E
FR
I
2ESI
BE
G20/G25
I
2E+
NO
DE
G20/G25
I
2ELL
YES
NL
G25/G25.3
I
2L
- I
2EK
25
2.15 m m
YES
2.3
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
LP
G31
I
3P
19.3
50/37
25.4
#56
LP16
YES
0.8
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
I
2H
LU
I
2E
FR
I
2ESI
BE
G20/G25
I
2E+
NO
DE
G20/G25
I
2ELL
YES
NL
G25/G25.3
I
2L
- I
2EK
25
#45
YES
2.3
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
LP
G31
I
3P
19.3
50/37
25.4
#56
LP16
YES
0.8
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
I
2H
LU
I
2E
FR
I
2ESI
BE
G20/G25
I
2E+
NO
DE
G20/G25
I
2ELL
YES
NL
G25/G25.3
I
2L
- I
2EK
25
2.15 m m
YES
2.3
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
LP
G31
I
3P
19.3
50/37
25.4
#56
LP16
YES
0.8
AT, BG, CH, CZ, DK, EE, FI, GB, GR, HU, IE, IT,
LT, LV, NO, PL, PT, RO, ES, SI, SK, SE, TR
I
2H
LU
I
2E
FR
I
2ESI
BE
G20/G25
I
2E+
NO
DE
G20/G25
I
2ELL
YES
NL
G25/G25.3
I
2L
- I
2EK
25
2.15 m m
YES
2.9
BG, CH, CY, CZ, FR, DE, GB, GR, HU, IE, IT,
LU, MT, NL, PL, PT, RO, ES, SI, SK, TR
LP
G31
I
3P
19.3
50/37
25.4
1.25 m m
LP16
YES
1.0
20/25
1.9/2.15
m m
2.5/2.9
SSHLV184R
Nat
G20
26.5
23.9
20
10
1.9 m m
N22
YES
2.5
EU GASTECHNICAL INFORMATION
10
1.9 m m
N22
YES
2.0
20/25
1.9/2.15
m m
2.0/2.3
SSHLV184
Nat
G20
21
18.9
20
10
#49
N22
YES
2.0
20/25
#49/#45
2.0/2.3
20
SSHLV14T
Nat
G20
21
18.9
20/25
1.9/2.15
m m
2.0/2.3
SSHLV14
Nat
G20
21
18.9
20
10
1.9 m m
N22
YES
2.0
2.4.
GAS CONNECTION
Your gas appliance will give you peak performance when the gas supply line is of sufficient size to
provide the correct gas pressure. The gas line must be installed to meet the local building codes or
National Fuel Gas Code ANSI Z223.1 Latest Edition. In Canada, install the appliance in accordance
with CAN/CGA-B149.1 or .2 and local codes. In Australia, install the appliance in accordance with
AS/NZS 5601. Gas line sizing requirements can be determined by your local gas company or, in North
America, by referring to the National Fuel Gas Code, Appendix C, Table C-4 (for natural gas) and
Table C-16 (for propane). The gas line needs to be large enough to supply the necessary amount of
fuel to all appliances without losing pressure
to any appliance.
A properly sized and installed gas line will deliver a supply pressure between 7.0” W.C. (17.4mbars,
1.74kPa) and 10.0” W.C. (24.9mbars, 2.49kPa) natural gas or between 11.0” W.C. (27.4mbars,
2.74kPa) and 13.0” W.C. (32.4mbars, 3.25kPa) for propane to all appliances connected to the supply
line, operating simultaneously at full demand. The pressure at the gas valve shall not exceed ½ PSI
(13.84 “WC, 34.5 mbar, 3.45 kPa). The gas supply connection to this appliance is located in the rear of
the appliance approximately 10-1/2” (26.7 cm) from the floor of the appliance when legs are used.
Each appliance is equipped to operate on one certain fuel type. The type of fuel with which the
appliance is intended to operate is stamped on the data plate, which is attached to the inside of the
door.
the Netherlands Only - Natural Gas
Dit toestel is afgesteld voor de toestelcategorie K (I2K) en is geschikt voor het gebruik van G en G+
distributiegassen volgens de specificaties zoals die zijn weergegeven in de NTA 8837:2012 Annex D
met een Wobbe-index van 43,46 – 45,3 MJ/m3 (droog, 0 °C, bovenwaarde) of 41,23 – 42,98 (droog, 15
°C, bovenwaarde). Dit toestel kan daarnaast worden omgebouwd en/of opnieuw worden afgeregeld
voor de toestelcategorie E (I2E) Dit houdt derhalve in dat het toestel: “geschikt is voor G+-gas en H-
gas, dan wel aantoonbaar geschikt is voor G+-gas en aantoonbaar geschikt is te maken voor H-gas” in
de zin van het “Besluit van 10 mei 2016 tot wijziging van het Besluit gastoestellen….”