INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
L20-407 rev.5 (06/19)
25
NOTICE
DO NOT run water through the filter return system. This will damage the pump and void
your warranty.
11. Scrub the inside of the tank using a cleaning brush safe for hot water. Care must be taken to
remove all the foreign material on the tank, heating tubes, sidewalls and other components in
the tank. Be careful not to loosen or damage the high limit or temperature probe during when
scrubbing.
12. Drain the water from the tank into a container that is large enough to hold the contents of the
tank and is suitable for use with 212°F(100°C) water.
Manual models: pull the blue handle out. The drain will open.
Automatic models: push and hold the key to enter the Fryer Control Menu. Press the #1
key. The message will display on the control. Press the #6 key (YES). The drain
will open; the control will display .
13. Once the tank has cooled, rinse it thoroughly with clean, potable water.
14. Remove all remaining water and residue with a clean dry cloth.
15. Clean and dry baskets, tube rack and basket hanger before reinstalling
16. Close the drain valve and fill the cooker tank with oil/shortening.
Manual models, push the blue handle in. The drain will close.
Automatic models, press the #6 key (YES). The drain will close; the control will display
.
To exit the Fryer Control Menu, press the ON/OFF key or the Filter key .
17. You can now fill the tank with oil/shortening.
9.3.2. TEMPERATURE CHECK
1. Use a high-grade pyrometer or digital thermometer suitable for temperature up to 380
°
F
(182°C). Place the thermometer in the oil above the tip of the fryer’s temperature probe with
in 1” (2.54 cm) 25.4 mm). Be sure not to touch the heat tube since this will measure
incorrect temperatures. Allow several minutes for the thermometer to equilibrate with the oil
temperature.
2. Press the Thermometer key on the computer, and compare the actual temperature to the
thermometer reading.
3. The two readings should be within a range of ± 5°F (±2.7°C) of each other. If the two
readings are not within the desired range, contact your local service representative or
Technical Support at the number on the back of this manual.