background image

 Page 5 

Unit Parts And Major Functions

2

Unit Parts

Fig. 2.1

Fig. 2.2

Unit Parts

    And Major 

Functions

Wall-mounted type

Duct / Ceiling type

Indoor unit

 1.   Panel frame
 2.   Rear air intake grille
 3.   Front panel
 4.   Air Purifying filter & Air filter (behind)
 5.   Horizontal louver
 6.   LCD display window
 7.   Vertical louver 
 8.   Manual control button (behind)
 9.   Remote controller holder

Outdoor unit

10.   Refrigerant connecting piping
11.   Connective cable
12.   Service valve
13.   Fan grill

Indoor unit

 1.   Air outlet
 2.   Air inlet
 3.   Air filter
 4.   Electric control box
 5.   Wired controller

Outdoor unit

 6.  Refrigerant connecting piping
 7.  Connective cable
 8.  Service valve
 9.  Fan grill

 Unit Parts 

 And Major 

Functions

Five Zone
(Quint)

Four Zone
(Quad)

Three Zone
(Triple)

Two Zone
(Dual)

Five Zone
(Quint)

Four Zone
(Quad)

Three Zone
(Triple)

Two Zone
(Dual)

Содержание YN-M Series

Страница 1: ...e this manual for your convenient future reference This manual only describes the outdoor unit of the system For detailed information on the indoor unit refer to the indoor unit s user manual MULTI SPLIT SYSTEM AIR CONDITIONER HEAT PUMP Owner s Manual YN M Series Inverter Models Two Three Four and Five Zones Dual Triple Quad and Quint Multi ...

Страница 2: ...Unit Parts and Major Functions 05 Manual Operation and Maintenance 09 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 04 1 2 3 ...

Страница 3: ... Page 3 Troubleshooting 10 a Common Problems 10 b Troubleshooting Tips 11 European Disposal Guidelines 12 4 5 ...

Страница 4: ...ath The appliance must be installed in accordance with all national regulations Failure to observe a caution may result in injury or equipment damage WARNING CAUTION DO NOT place items that might be affected by moisture damage under the indoor unit Condensation can occur at a relative humidity of 80 DO NOT expose heat producing appliances to cold air or place them under the indoor unit This may ca...

Страница 5: ...ver 8 Manual control button behind 9 Remote controller holder Outdoor unit 10 Refrigerant connecting piping 11 Connective cable 12 Service valve 13 Fan grill Indoor unit 1 Air outlet 2 Air inlet 3 Air filter 4 Electric control box 5 Wired controller Outdoor unit 6 Refrigerant connecting piping 7 Connective cable 8 Service valve 9 Fan grill Unit Parts And Major Functions Five Zone Quint Four Zone Q...

Страница 6: ...unit 6 Refrigerant connecting piping 7 Connective cable 8 Service valve 9 Fan grill Fig 2 4 Indoor unit 1 Drain pump condensate removal pump 2 Drain hose 3 Air outlet 4 Air inlet 5 Return air grill 6 Display panel 7 Remote controller Outdoor unit 8 Refrigerant connecting piping 9 Connective cable 10 Service valve 11 Fan grill Five Zone Quint Four Zone Quad Three Zone Triple Two Zone Dual Five Zone...

Страница 7: ...y stop When power returns the operation light on the indoor unit will flash To restart the unit press the ON OFF button on the remote control If the system has the auto restart function enabled the unit will restart with the same settings without any action by default White mist may emerge from the indoor unit White mist may be generated due to a large temperature difference between the air inlet a...

Страница 8: ...of the indoor unit when cooling during relatively high humidity defined as higher than 80 Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed Heating mode for cooling and heating models only The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating When the outdoor temperature falls heat drawn in by the air cond...

Страница 9: ...aler or a customer service center if the unit requires servicing When the air conditioner is to be used again Use a dry cloth to wipe off any dust that has accumulated on the rear air intake grille in order to avoid the dust being dispersed from the indoor unit Check that the wiring is not broken off or disconnected Check that the air filter is installed Check if the air outlet or inlet is blocked...

Страница 10: ...de to FAN mode The unit changes its setting to prevent frost from forming onto the unit Once the temperature increases the unit will start operating again The set temperature has been reached at which point the unit turns off the compressor The unit will resume operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between th...

Страница 11: ...he temperature setting The heat exchanger on the indoor or outdoor unit is dirty Clean the affected heat exchanger The air filter is dirty Remove the filter and clean it according to instructions The air inlet or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the ...

Страница 12: ...ipal waste When disposing of this appliance you have the following options Dispose of the appliance at a designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will also take back the old appliance free of charge Sell the appliance to certified scrap metal dealers NOTE Disposing of this appl...

Страница 13: ...ues Consult with the sales agency or manufacturer for details is a registered trademark of Parker Davis HVAC International Inc Parker Davis HVAC International Inc 2250 NW 102 Place Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 email info pd hvac com Website www pd hvac com Copyright 2017 Parker Davis HVAC International Inc All rights reserved ...