11
Engb
Vertical expansion of cluster using the CP-XY1CON1
1
3
2
!
Using the CP-XY1CON1, the cluster formed using the CP-XY1DF1 can be
further expanded vertically. Using the XY-1 and XY-2E metal fittings, up to three
units can be linked horizontally with the CP-XY1DF1 and up to three units can
be linked vertically with the CP-XY1CON1, for a total of nine linked units. In
addition to that, XY-2 can be attached to the bottommost units.
!
Using the M10 countersunk bolts and four vertical connection plates that come
with the metal fittings, fix the sides of the top and bottom speakers.
WARNING
!
When installing the CP-XY1CON1 with the XY-1 and XY-2E, make sure to
tighten the bolts to the torques specified in the table below.
M10 bolts
: 15 N·m
!
Do not attempt to use this product with components other than the specified
speaker.
!
Be sure to use the supplied accessory screws.
!
After mounting the speaker with the cradle, never loosen any of its accessory
installation screws, since the speaker could fall or other accidents could
occur.
1
CP-XY1DF1 - Top-plate
2
CP-XY1DF1 - Rear-plate
3
CP-XY1CON1 - Vertical connection plate
Mo
un
tin
g an
d ri
gg
in
g o
pti
on
s