6.2 USING RS-232C COMMANDS
¶
How to switch the RS-232C control setting to ON by Service Factory Mode
¶
How to switch the RS-232C control setting to ON by Remote Control unit
Remote control unit
START
INFORMATION
VERSION
INITIALIZE
SYNC DET
MUTE
Select
INITIALIZE
mode
INITIALIZE
SR+
⇔
: OFF
Select
SR+
Enter the Service Factory mode
232C ON/OFF switch
Left
Right
ON
↔
OFF
The circuitry for the PDP-436SXE/RXE is as shown in the figure below, and activation/deactivation (ON/OFF) of RS-232C control is selectable.
As OFF is selected at shipment, to enable RS-232C control when servicing, it is necessary to switch the setting to ON.
*
Set SR+ to OFF to switch the RS-232C
control setting to ON.
Hold the
VOLUME
or key on the remote control unit pressed for 3-10 seconds during Standby mode.
Then within 3 seconds after the key is released, hold the
2-screen
key on the remote control unit pressed for 3-10 seconds.
Then within 3 seconds after the key is released, use the
SET
key on the remote control unit to set to RS-232C.
The path is switched to that for RS-232C control. The baud rate becomes 9,600 bps.
[ To Switch RS-232C control to ON ]
Hold the
VOLUME
or key on the remote control unit pressed for 3-10 seconds during Standby mode.
Then within 3 seconds after the key is released, hold the
2-screen
key on the remote control unit pressed for 3-10 seconds.
Then within 3 seconds after the key is released, use the
HOME MUNU
key on the remote control unit to set to RS-232C.
The path is switched to that for SR+, and RS-232C control becomes OFF.
[ TIPS ]
*
During IF Standby (once 10 seconds or more has passed after the LED goes dark during communication), the first keypress
may not be accepted. In such a case, for a key operation, first press any key other than the POWER key and CH keys, then
the desired key.
Note: For switching the RS-232C control setting, use the remote control unit supplied with the PDP-436XDE, etc., because the
2-Screen key (for multiscreen) is not provided with the remote control unit supplied with the PDP-436SXE/RXE.
[ To Switch RS-232C control to OFF ]
Содержание PDP-436RXE
Страница 9: ...PDP 436SXE 9 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 25: ...PDP 436SXE 25 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only ...
Страница 27: ...PDP 436SXE 27 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only SXE Only ...
Страница 145: ...PDP 436SXE 145 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT OBE MAIN ASSY IC4804 AV SW ...
Страница 146: ...PDP 436SXE 146 1 2 3 4 1 2 3 4 C D F A B E Block Diagram R2S11001FT OBE MAIN ASSY IC4806 Component SW IC ...