PDP-436SXE
99
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Note:
• When the command FAJ, UAJ, or CBU is executed, only high-order one-byte (0x00 or 0xF0) key data will be written to the
EEPROM, and lower-order one-byte (0x63) data will not be changed.
• It takes at least 350 ms from reception of the command FAJ until an echo is sent back, because data are copied to the
backup EEPROM.
Command
Format
Operation
Remarks
Effective
Operation Modes
Control (by the microcomputer itself)
[FAJ]
During FAY
To make the flag setting that
indicating that adjustment of the
panel unit has been completed
Writing 00 to the 4-kbyte ROM and
copying to the 2-kbyte ROM
This takes at least 350 ms.
[UAJ]
To make the flag setting that
indicating that adjustment of the
main unit has not been completed
Writing F0 to the 4-kbyte ROM
[CBU]
To make the flag setting that
indicating that backup data
have not been copied
Writing F0 to the 2-kbyte ROM
The backup ROM is
initialized.
[BCP]
To copy Digital backup data
to EEPROM
Copying backup data
When the flag indicating that the production line adjustments (SUS waveform, voltage margin, and panel WB) for the panel
unit have been completed is set to on, data stored from Addresses 0x0000 to 0X00FF in the digital EEPROM are copied to
the same addresses of the backup EEPROM. Copying will be executed immediately before the relay of normal operation is off.
• When the command BCP is received while a warning indicating that backup copying has not been completed is displayed
(conditions: Digital EEPROM = not adjusted, and backup EEPROM = adjusted), backed-up data will be copied to the Digital
EEPROM, and various adjustment values related to Factory mode will be readjusted. Then LED warning indication will be
shut off, and normal LED indication will be restored.
• If the backup EEPROM has not been adjusted when the command BCP is received (0x0063 is not written to all three
addresses of the key data), copying of the backup data is not possible, and "XXX" is returned.
Address
0x0000
0x00FF
Address
0x00
0xFF
0x0100
0x01FF
EEPROM for the module
microcomputer
Data that need backup, such as
adjustment values for the panel
unit and the data from the hour
meter, etc
Data that do not need backup,
such as raster mask color
EEPROM for data backup
Writing when the power is
off, etc.
Executing copying with the
command BCP
Data that need backup, such as
adjustment values for the panel
unit and the data from the hour
meter
7
Backup function for adjustment values for the panel unit • • • [FAJ/UAJ/CBU/BCP]
When the OB DIGITAL Assy is to be replaced, adjustment values can be copied from the backup EEPROM to the
EEPROM of the Assy for service.
Содержание PDP-436RXE
Страница 9: ...PDP 436SXE 9 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 25: ...PDP 436SXE 25 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only ...
Страница 27: ...PDP 436SXE 27 5 6 7 8 5 6 7 8 C D F A B E SXE Only SXE Only SXE Only ...
Страница 145: ...PDP 436SXE 145 5 6 7 8 5 6 7 8 C D F A B E Block Diagram R2S11002AFT OBE MAIN ASSY IC4804 AV SW ...
Страница 146: ...PDP 436SXE 146 1 2 3 4 1 2 3 4 C D F A B E Block Diagram R2S11001FT OBE MAIN ASSY IC4806 Component SW IC ...