background image

PDP-506PE

59

5

6

7

8

5

6

7

8

C

D

F

A

B

E

Conversion chart for the Vofs (Commands vs. Common voltage values for the 50-inch and 43-inch models)

Command

Voltage value 

[V] for

common sizes

Command

Voltage value 

[V] for

common sizes

Command

Voltage value 

[V] for

common sizes

Command

Voltage value 

[V] for

common sizes

Command

Voltage value 

[V] for

common sizes

VOF000

14.09

VOF056

24.55

VOF112

35.01

VOF168

45.47

VOF224

55.93

VOF001

14.28

VOF057

24.74

VOF113

35.20

VOF169

45.66

VOF225

56.12

VOF002

14.46

VOF058

24.92

VOF114

35.38

VOF170

45.85

VOF226

56.31

VOF003

14.65

VOF059

25.11

VOF115

35.57

VOF171

46.03

VOF227

56.49

VOF004

14.84

VOF060

25.30

VOF116

35.76

VOF172

46.22

VOF228

56.68

VOF005

15.02

VOF061

25.48

VOF117

35.95

VOF173

46.41

VOF229

56.87

VOF006

15.21

VOF062

25.67

VOF118

36.13

VOF174

46.59

VOF230

57.05

VOF007

15.40

VOF063

25.86

VOF119

36.32

VOF175

46.78

VOF231

57.24

VOF008

15.58

VOF064

26.04

VOF120

36.51

VOF176

46.97

VOF232

57.43

VOF009

15.77

VOF065

26.23

VOF121

36.69

VOF177

47.15

VOF233

57.61

VOF010

15.96

VOF066

26.42

VOF122

36.88

VOF178

47.34

VOF234

57.80

VOF011

16.14

VOF067

26.61

VOF123

37.07

VOF179

47.53

VOF235

57.99

VOF012

16.33

VOF068

26.79

VOF124

37.25

VOF180

47.71

VOF236

58.17

VOF013

16.52

VOF069

26.98

VOF125

37.44

VOF181

47.90

VOF237

58.36

VOF014

16.70

VOF070

27.17

VOF126

37.63

VOF182

48.09

VOF238

58.55

VOF015

16.89

VOF071

27.35

VOF127

37.81

VOF183

48.27

VOF239

58.73

VOF016

17.08

VOF072

27.54

VOF128

38.00

VOF184

48.46

VOF240

58.92

VOF017

17.27

VOF073

27.73

VOF129

38.19

VOF185

48.65

VOF241

59.11

VOF018

17.45

VOF074

27.91

VOF130

38.37

VOF186

48.83

VOF242

59.30

VOF019

17.64

VOF075

28.10

VOF131

38.56

VOF187

49.02

VOF243

59.48

VOF020

17.83

VOF076

28.29

VOF132

38.75

VOF188

49.21

VOF244

59.67

VOF021

18.01

VOF077

28.47

VOF133

38.93

VOF189

49.39

VOF245

59.86

VOF022

18.20

VOF078

28.66

VOF134

39.12

VOF190

49.58

VOF246

60.04

VOF023

18.39

VOF079

28.85

VOF135

39.31

VOF191

49.77

VOF247

60.23

VOF024

18.57

VOF080

29.03

VOF136

39.49

VOF192

49.96

VOF248

60.42

VOF025

18.76

VOF081

29.22

VOF137

39.68

VOF193

50.14

VOF249

60.60

VOF026

18.95

VOF082

29.41

VOF138

39.87

VOF194

50.33

VOF250

60.79

VOF027

19.13

VOF083

29.59

VOF139

40.05

VOF195

50.52

VOF251

60.98

VOF028

19.32

VOF084

29.78

VOF140

40.24

VOF196

50.70

VOF252

61.16

VOF029

19.51

VOF085

29.97

VOF141

40.43

VOF197

50.89

VOF253

61.35

VOF030

19.69

VOF086

30.15

VOF142

40.62

VOF198

51.08

VOF254

61.54

VOF031

19.88

VOF087

30.34

VOF143

40.80

VOF199

51.26

VOF255

61.72

VOF032

20.07

VOF088

30.53

VOF144

40.99

VOF200

51.45

VOF033

20.25

VOF089

30.71

VOF145

41.18

VOF201

51.64

VOF034

20.44

VOF090

30.90

VOF146

41.36

VOF202

51.82

VOF035

20.63

VOF091

31.09

VOF147

41.55

VOF203

52.01

VOF036

20.81

VOF092

31.28

VOF148

41.74

VOF204

52.20

VOF037

21.00

VOF093

31.46

VOF149

41.92

VOF205

52.38

VOF038

21.19

VOF094

31.65

VOF150

42.11

VOF206

52.57

VOF039

21.37

VOF095

31.84

VOF151

42.30

VOF207

52.76

VOF040

21.56

VOF096

32.02

VOF152

42.48

VOF208

52.94

VOF041

21.75

VOF097

32.21

VOF153

42.67

VOF209

53.13

VOF042

21.94

VOF098

32.40

VOF154

42.86

VOF210

53.32

VOF043

22.12

VOF099

32.58

VOF155

43.04

VOF211

53.50

VOF044

22.31

VOF100

32.77

VOF156

43.23

VOF212

53.69

VOF045

22.50

VOF101

32.96

VOF157

43.42

VOF213

53.88

VOF046

22.68

VOF102

33.14

VOF158

43.60

VOF214

54.06

VOF047

22.87

VOF103

33.33

VOF159

43.79

VOF215

54.25

VOF048

23.06

VOF104

33.52

VOF160

43.98

VOF216

54.44

VOF049

23.24

VOF105

33.70

VOF161

44.16

VOF217

54.63

VOF050

23.43

VOF106

33.89

VOF162

44.35

VOF218

54.81

VOF051

23.62

VOF107

34.08

VOF163

44.54

VOF219

55.00

VOF052

23.80

VOF108

34.26

VOF164

44.72

VOF220

55.19

VOF053

23.99

VOF109

34.45

VOF165

44.91

VOF221

55.37

VOF054

24.18

VOF110

34.64

VOF166

45.10

VOF222

55.56

VOF055

24.36

VOF111

34.82

VOF167

45.29

VOF223

55.75

Conversion charts for electronic VRs: Conversion chart for the Vofs

Содержание PDP-436PU

Страница 1: ... PDP 506PU THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL S AND TYPE S This service manual should be used together with the following manual s Model Type Power Requirement Remarks PDP 506PE WYVI AC220 240V PDP 506PU KUCXC AC120V Model No Order No Remarks PDP 506PE PDP 506PU ARP3268 SCHEMATIC DIAGRAM PCB CONNECTION DIAGRAM Note Media Receivers up to Generation 5 G5 cannot be connected with this u...

Страница 2: ...e put back in place such as barriers nonmetallic knobs adjustment and compartment covershields isolation resistor capacitor etc 3 When service is required observe the original lead dress Extra precaution should be taken to assure correct lead dress in the high voltage circuitry area 4 Always use the manufacture s replacement components Especially critical components as indicated on the circuit dia...

Страница 3: ... Any current measured must not exceed 0 5mA ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE SET TO THE CUSTOMER PRODUCT SAFETY NOTICE Many electrical and mechanical parts in PIONEER set have special safety related characteristics These are often not evident from visual inspection nor the protection afforded...

Страница 4: ...r Switch S1 4 Fuse In the POWER SUPPLY Unit 5 STB Transformer and Converter Transformer In the POWER SUPPLY Unit 6 Other primary side of the POWER SUPPLY Unit High Voltage Generating Point The places where voltage is 100V or more except for the charged places described above If the places are touched there is a risk of electric shock If the procedures described in 7 1 5 POWER ON OFF FUNCTION FOR T...

Страница 5: ...the product Please check that neither solder debris nor screws remain inside the product 8 There should be no semi broken wires scratches melting etc on the coating of the power cord Damaged power cords may lead to fire accidents so please be sure that there are no damages If you find a damaged power cord please exchange it with a suitable one 9 There should be no spark traces or similar marks on ...

Страница 6: ...Y 27 3 7 HD DIGITAL ASSY 28 3 8 HD AUDIO ASSY 29 3 9 POWER SUPPLY UNIT 30 3 10 WAVEFORMS 31 5 PCB PARTS LIST 33 6 ADJUSTMENT 41 6 1 ADJUSTMENT REQUIRED WHEN THE SET IS REPAIRED OR REPLACED 41 6 2 RS 232C COMMAND 42 6 3 METHOD FOR REPLACING THE SERVICE PANEL ASSY 58 7 GENERAL INFORMATION 62 7 1 DIAGNOSIS 62 7 1 1 PCB LOCATION 62 7 1 2 DIAGNOSIS OF SHUTDOWN POWER DOWN INDICATED BY LEDS 63 7 1 3 OVER...

Страница 7: ...cessories FOCUS WOW SRS and symbol are trademarks of SRS Labs Inc FOCUS and SRS technologies are incorporated under license from SRS Labs Inc This product includes FontAvenue fonts licensed by NEC Corporation FontAvenue is a registered trademark of NEC Corporation HDMI the HDMI logo and High Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC The names of ...

Страница 8: ...dicates the importance of the safety factor of the part Therefore when replacing be sure to use parts of identical designation Screws adjacent to mark on product are used for disassembly For the applying amount of lubricants or glue follow the instructions in this manual In the case of no amount instructions apply as you think it appropriate NOTES 14 8 10 13 12 11 9 1 4 2 3 PDP 506PE only PDP 506P...

Страница 9: ...Power Cord Case See Contrast table 2 13 Under Carton See Contrast table 2 14 Upper Carton See Contrast table 2 15 Mirror Mat See Contrast table 2 16 Caution Card See Contrast table 2 Mark No Symbol and Description PDP 506PE WYVI PDP 506PU KUCXC 1 Power Cord ADG1214 ADG1215 4 Polyethylene Bag S AHG1338 AHG1348 NSP 5 Catalogue Bag AHG1340 AHG1347 NSP 6 Warranty Card ARY1114 ARY1145 7 Ferrite Core AT...

Страница 10: ...PDP 506PE 10 1 2 3 4 1 2 3 4 C D F A B E 2 2 REAR SECTION To Power Switch Refer to 2 3 FRONT SECTION 5 1 3 16 16 15 7 6 15 15 15 15 15 16 11 4 8 11 4 15 15 15 15 2 13 12 14 5 PDP 506PE only ...

Страница 11: ...34 5 AC Cushion AEC2035 NSP 6 Model Label See Contrast table 2 7 Caution Label See Contrast table 2 8 AC Label PE See Contrast table 2 9 10 11 Screw 3 x 40P ABA1332 12 Hexagon Head Screw BBA1051 13 Screw PMZ26P060FTB 14 Screw BPZ30P080FTB 15 Screw AMZ30P060FTB 16 Screw TBZ40P080FTB Mark No Symbol and Description PDP 506PE WYVI PDP 506PU KUCXC NSP 6 Model Label 506PE AAL2661 Not used NSP 6 Model La...

Страница 12: ...PDP 506PE 12 1 2 3 4 1 2 3 4 C D F A B E 2 3 FRONT SECTION Refer to 2 4 CHASSIS SECTION 1 2 1 7 8 3 7 10 10 8 9 4 5 6 7 2 7 PDP 506PE only ...

Страница 13: ...rt No 1 Front Case Assy 506PE AMB2861 2 Corner Cushion AEB1416 3 Pioneer Name Plate AAM1098 4 Power Button AAD4133 5 Coil Spring ABH1120 6 Blind Cushion AEB1415 7 Insulation Sheet A AED1283 8 Insulation Sheet B AED1284 9 Power Display Label 506 See Contrast table 2 10 Screw Rivet AEC1877 Mark No Symbol and Description PDP 506PE WYVI PDP 506PU KUCXC 9 Power Display Label 506 AAX3217 Not used ...

Страница 14: ... CHASSIS SECTION 1 2 2 1 From AC Inlet From POWER SUPPLY P3 To HD DIGITAL CN3003 To HD DIGITAL CN3003 Refer to 2 5 CHASSIS SECTION 2 2 19 19 18 17 17 9 1 8 16 14 22 22 22 21 3 4 23 22 7 17 23 14 13 23 20 12 11 6 17 20 23 17 17 17 11 5 2 10 10 12 ...

Страница 15: ...Front Chassis VR 50 AMA1015 7 Sub Frame L Assy 506 ANA1860 8 Sub Frame R Assy 506 ANA1861 9 Front Chassis H Assy 50 ANA1883 10 Panel Holder H 50 ANG2769 11 Panel Holder V1 50 ANG2770 12 Panel Holder V2 50 ANG2771 13 Cushion AEB1424 14 Wire Saddle AEC1745 15 16 Nyron Rivet AEC1671 17 Screw ABZ30P080FTC 18 Screw AMZ30P060FTB 19 Screw APZ30P080FTB 20 Screw BBZ30P060FTC 21 Screw BPZ30P080FTB 22 Screw ...

Страница 16: ...O P P A R R O C D F D C H I I H B A 1 2 To Power Switch To HD LED CN1671 HD IR CN1681 9 9 9 31 31 11 10 31 32 32 25 24 32 32 32 32 32 40 33 32 30 41 41 41 32 32 33 36 36 36 37 36 41 41 40 40 27 2 3 1 40 40 36 20 40 40 4 16 30 35 34 6 26 21 23 31 13 18 12 5 14 15 19 41 7 41 9 36 41 40 41 17 32 39 29 22 41 41 28 8 ...

Страница 17: ...0 See Contrast table 2 19 6P Housing Wire J111 ADX3120 20 3P Housing Wire J113 See Contrast table 2 21 14P Housing Wire J104 ADX3158 22 3P Housing Wire J105 ADX3159 23 9P Housing Wire J101 ADX3186 24 8P Housing Wire J102 ADX3187 25 5P Housing Wire J106 ADX3188 26 6P Housing Wire J107 ADX3189 27 Conductive Plate XA ANG2776 28 FC Stay ANG2815 29 Binder AEC 093 NSP 30 PCB Spacer AEC1188 31 Flat Clamp...

Страница 18: ...SSY 506P AWU1134 34 30 2 26 23 23 23 24 20 20 25 8 2 1 2 2 21 9 12 11 7 7 7 3 5 5 5 38 5 5 4 7 19 21 23 23 23 10 9 12 11 10 9 12 11 10 9 35 13 12 11 10 6 6 6 6 33 18 14 30 35 23 30 30 32 31 30 16 21 34 34 34 15 32 30 17 37 for transport 34 34 31 31 31 34 29 29 ...

Страница 19: ...MR3454 8 Tube Cover AMR3445 9 Address Heatsink 50 ANH1635 10 Address Silicone A AEH1093 11 Address Silicone B AEH1094 12 Screw BBB30P120FNI 13 Front Chassis VL 50 AMA1014 14 Front Chassis VR 50 AMA1015 15 Sub Frame L Assy 506 ANA1860 16 Sub Frame R Assy 506 ANA1861 17 Front Chassis H Assy 50 ANA1883 18 Conductive Plate XA ANG2776 19 Cushion AEB1424 NSP 20 PCB Spacer AEC1188 21 Wire Saddle AEC1745 ...

Страница 20: ...PDP 506PE 20 1 2 3 4 1 2 3 4 C D F A B E 3 BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 3 1 OVERALL CONNECTION DIAGRAM ...

Страница 21: ...ing service parts be sure to refer to EXPLODED VIEWS and PARTS LIST or PCB PARTS LIST The mark found on some component parts indicates the importance of the safety factor of the part Therefore when replacing be sure to use parts of identical designation ...

Страница 22: ...53 Driver IC V ADR3 V 60V V 5V Resonance Block IC1552 Driver IC V ADR2 Resonance Block IC1551 Driver IC V ADR1 Resonance Block AD1 AD2 CN2802 CN2702 Y6 Y5 Y4 Y1 A2 Left DC Detect Block IC3754 EEP ROM IC3751 Power Amp IC IC3752 Regulator Buffer IC3753 WOW Volume IC 3 3V SCL SCL SDA SDA A_NG_B L_Audio R_Audio A_STBY_B A_Mute 3 3V 16 5V IC5V Drive Signal Vprst Vprst PSUS PSUS 9 0V 9 0V 9 0V 16 5V 16 ...

Страница 23: ... PRIMARY 16 5V 16 5V 8V STA3 3V PS_PD EXT_PD RELAY VSUS_ADJ VSUS_CONT 60V IC202 6 5V V 3V ACT 16 5V 16 5V 16 5V 16 5V VF 16 5V Wire haerness VRN 5V 5V 5V 5V 6 5V V 3V_D V 1V_D V 8V PSIZE V 8V DC DC Converter Module AXY1116 DAC Mask Pulse Width IC3151 M30620FCPGP Module Ucom IC3401 PEG122C K Sequence Processor IC3001 TMDS Receiver IC3301 Flash Memory Vsus_ADJ V 8V V 8V V 8V V 8V V 3V STB REM STB_MT...

Страница 24: ...A K LVDS Receiver CN1501 V ADR5 CN1502 Resonance Block IC1554 Driver IC V ADR4 CLK LE HBLK LBLK R G B V 3V V 8V AN P BN P CN P DN P CLKN P Resonance Block IC1553 Driver IC V ADR3 V 60V V 5V Resonance Block IC1552 Driver IC V ADR2 Resonance Block IC1551 Driver IC V ADR1 Resonance Block AD1 AD2 ...

Страница 25: ...ER 50 SCAN A ASSY LOWER SA1 CN2802 CN2702 SB1 IC2801 Scan IC IC2701 Scan IC IC2702 Scan IC IC2703 Scan IC IC2704 Scan IC IC2705 Scan IC IC2706 Scan IC IC2802 Scan IC IC2803 Scan IC IC2804 Scan IC IC2805 Scan IC IC2806 Scan IC Serial Data PSUS Scan Signal VH IC5V PSUS Scan Signal VH IC5V ...

Страница 26: ...SYS 50 X DRIVE ASSY SUS CLAMP 1 ASSY 16 5V 16 5V 16 5V 16 5V VF 16 5V VRN 5V 5V 5V 5V 6 5V VSUS CL1 SUS CLAMP 2 ASSY VSUS CL2 X1 Logic Block Regulator 15V DC DC Conv IC1101 DK Mod Resonance Block IC1202 Mask Mod VRN DC DC Conv Reset Block X4 X3 X2 VSUS VSUS VSUS SUS OUT PSUS Drive Signal ...

Страница 27: ...16 5V 16 5V VSUS IC5V VH IC2252 Mask Mod Vprst Reg Reset Block Offset Block VOFS DC DC Conv 5V 5V 16 5V 5V 5V 16 5V 16 5V 16 5V Scan Signal 60V IC5V IC5V 5V VOFS VOFS VSUS 16 5V SUSOUT 6 5V 5V VF VSUS IC2253 Mask Mod IC2101 DK Mod Resonance Block Logic Block Regulator Soft D Block IC5V VF DC DC Conv Photo Coupler Block VH DC DC Conv ...

Страница 28: ...ence Processor IC3001 TMDS Receiver IC3301 Flash Memory Vsus_ADJ V 8V V 8V V 8V V 8V V 3V STB REM STB_MT LVDS AUDIO L AUDIO R PD PS_PWDN SQ_PD PD_MUTE XSUS OR OR UART SW D5 D6 D3 D2 D1 H DET Bus Buffer Bus Buffer LED_R LED_B REM SCAN_PD YDRV_PD YSUS_PD YDD_PD SCN5V_PD SCAN YSUS Vofs_ADJ VYPRST_ADJ SCL SCA RELAY PD_TRIGGER AC_DET DRF XSUSTN_PD XDD_CNV_PD XDRIVE_PD ADR_PD1 LVDS VD HD FIELD SCL SDA S...

Страница 29: ... SP TERMINAL Right R_OUT R_OUT SPEAKERS L_OUT L_OUT A3 A1 A2 Left DC Detect Block IC3754 EEP ROM IC3751 Power Amp IC IC3752 Regulator Buffer IC3753 WOW Volume IC 3 3V SCL SCL SDA SDA A_NG_B L_Audio R_Audio A_STBY_B A_Mute 3 3V 16 5V 9 0V 9 0V 9 0V 16 5V 16 5V ...

Страница 30: ...SUS Switching Switching SECONDARY PRIMARY 16 5V 16 5V 8V STA3 3V PS_PD EXT_PD RELAY VSUS_ADJ VSUS_CONT 60V IC202 6 5V Q703 PFC Q101 Q102 Q103 Q704 T702 T902 T101 T502 RY102 Switching Switching NEUTRAL LIVE Switching D109 390V D103 D107 D108 Q901 Q902 IC101 Switching Switching Q501 Q502 ...

Страница 31: ... 1V div H 2msec div CH3 IC1555 pin 16 CLK V 1V div H 2msec div CH4 IC1555 pin 14 LE V 1V div H 2msec div CH5 IC1555 pin 19 HBLK V 1V div H 2msec div CH6 IC1555 pin 17 LBLK V 1V div H 2msec div 3 3 1 3 2 3 3 3 4 3 5 3 6 Incoming signal of TCP Resonance part Input VIDEO Signal Checkered pattern of Black White MKSS13 CH1 IC1555 pin 3 VDD2 V 10V div H 200nsec div CH2 IC1555 pin 9 A3 V 1V div H 200nsec...

Страница 32: ...E Assy CH2 TP2008 CLK K2002 GND D V 1V div H 2msec div X DRIVE Assy CH3 TP2003 SI H K2002 GND D V 1V div H 2msec div X DRIVE Assy CH4 TP2004 CLR K2002 GND D V 1V div H 2msec div X DRIVE Assy CH5 TP2005 OC2 K2002 GND D V 1V div H 2msec div X DRIVE Assy CH6 TP2006 OC1 K2002 GND D V 1V div H 2msec div X DRIVE Assy 5 5 1 5 2 5 3 5 1 5 2 5 3 Reset pulse signal CH1 R1277 XPSUS K1203 SUSGND V 100V div H ...

Страница 33: ... and Description PDP 506PE WYVI PDP 506PU KUCXC NSP 1 PANEL CHASSIS 506 ASSY AWU1143 AWU1143 NSP 2 50 ADDRESS ASSY AWV2208 AWV2208 NSP 2 50 SCAN ASSY AWV2211 AWV2211 NSP 3 50 SCAN A ASSY AWW1026 AWW1026 NSP 3 50 SCAN B ASSY AWW1027 AWW1027 NSP 1 50 X DRIVE ASSY AWV2257 AWV2209 or AWV2257 2 50 X DRIVE ASSY AWW1075 AWW1020 or AWW1075 2 SUS CLAMP 1 ASSY AWW1022 AWW1022 2 SUS CLAMP 2 ASSY AWW1023 AWW1...

Страница 34: ...250V ACG1088 C2731 C2741 C2751 0 1U 250V ACG1088 C2710 C2720 C2730 C2740 C2750 CCSRCH181J50 C2760 CCSRCH181J50 C2708 C2709 C2718 C2719 CCSRCH331J50 C2728 C2729 C2738 C2739 CCSRCH331J50 C2748 C2749 C2758 C2759 CCSRCH331J50 C2705 C2707 C2715 C2717 CCSRCH390J50 C2725 C2727 C2735 C2737 CCSRCH390J50 C2745 C2747 C2755 C2757 CCSRCH390J50 C2703 C2713 C2723 C2733 C2743 CKSRYB105K6R3 C2753 CKSRYB105K6R3 RES...

Страница 35: ...RS L1204 L1211 INDUCTOR ATH1186 F1201 INDUCTOR CTF1449 L1201 L1205 L1231 LFEA100J Mark No Description Part No CAPACITORS C1214 C1217 ACE1178 C1212 C1213 ACH1423 C1231 CEHAT101M10 C1206 CEHAT101M25 C1283 CEHAT2R2M2E C1208 CEHAT470M16 C1222 C1272 CEHAT470M25 C1221 CKSRYB105K6R3 C1204 C1207 C1223 C1251 C1253 CKSRYF104Z50 C1273 CKSRYF104Z50 C1220 CKSYB105K25 RESISTORS R1204 ACN1166 R1213 ACN1168 R1276...

Страница 36: ... 470p 630V ACG1126 C2106 CCG1186 C2101 C2145 CKSRYB105K6R3 Mark No Description Part No C2141 C2143 C2144 CKSSYB104K10 C2102 CKSYB105K25 RESISTORS R2101 ACN1174 R2142 R2143 RS1 10S1003F R2103 R2107 RS1 10S104J R2146 R2149 RS1 16S5601F R2147 R2151 RS1 16S6801F R2102 RS2MMF100J R2108 RS3LMF100J Other Resistors RS1 16S J 50Y SUS BLOCK SEMICONDUCTORS IC2252 IC2253 AXF1141 IC2350 MM1565AF IC2250 PS9117 ...

Страница 37: ...D2536 UDZS4R7 B D2530 D2531 UDZS8R2 B COILS AND FILTERS T2503 CONVERTER TRANS ATK1158 L2501 LFEA101J Mark No Description Part No CAPACITORS C2531 ACE1177 C2516 ACH1360 C2532 ACH1425 C2513 ACH1428 C2520 CEHAT101M16 C2515 CEHAT101M25 C2528 CEHAT221M16 C2514 C2525 C2534 CKSRYB104K16 C2521 C2533 C2535 CKSRYB104K25 RESISTORS R2553 RAB4C472J R2558 RS1 10S0R0J R2533 R2556 RS1 10S104J R2534 R2535 R2541 RS...

Страница 38: ...043 CKSSYF104Z16 RESISTORS R3007 RAB4C220J R3008 R3013 RAB4C470J R3018 RAB4C472J R3021 RS1 16S3900F Other Resistors RS1 16S J Mark No Description Part No OTHERS CN3003 PH CONNECTOR 6P AKM1277 CN3004 PH CONNECTOR 12P AKM1298 JA3001 DVI CONNECTOR AKP1276 JA3002 MDR CONNECTOR AKP1277 MODULE UCOM BLOCK SEMICONDUCTORS IC3156 BR24L04FJ W IC3151 M30620FCPGP U5C IC3157 M62334FP IC3158 MM1522XU IC3155 SN74...

Страница 39: ...OLID INDUCTOR QTL1011 Mark No Description Part No HD IR ASSY SEMICONDUCTORS Q1681 2SC4116 D1681 DA204U CAPACITORS C1681 CEVW470M6R3 C1682 CKSRYB103K50 C1683 CKSSYB102K50 C1684 CKSSYF104Z16 RESISTORS All Resistors RS1 16S J OTHERS CN1681 3P L TYPE PLUG KM200NA3L V1681 REMOTE RECEIVER UNIT RPM7240 H4 HD AUDIO ASSY OTHERS J3901 1P BOARD IN WIRE ADX3123 AUDIO AMP BLOCK SEMICONDUCTORS IC3754 BR24L02FJ ...

Страница 40: ...PPING TERMINAL VNF1084 KN3752 WRAPPING TERMINAL VNF1084 STTERMINAL BLOCK COILS AND FILTERS L3901 L3902 LINE FILTER ATF1206 CAPACITORS C3906 C3908 C3914 C3916 CCSRCH101J50 C3903 C3911 CKSRYB332K50 C3904 C3912 CKSRYF473Z50 RESISTORS R3901 R3904 RD1 2MMF100J OTHERS JA3901 SPEAKER TERMINAL AKE1061 POWER SUPPLY UNIT POWER SUPPLY Unit has no service part Mark No Description Part No ...

Страница 41: ...ngs 3 Use a stable AC power supply 50 Y DRIVE Assy No adjustment required POWER SUPPLY Unit Clear the history data on the number of power ons Refer to 7 1 7 HOW TO CLEAR HISTORY DATA HD DIGITAL Assy Writing of backup data is required Refer to the 7 1 6 BACKUP WHEN THE MAIN UNIT IS ADJUSTED 50 X DRIVE Assy No adjustment required Other assemblies No adjustment required Service Panel Refer to the 6 3...

Страница 42: ... communication device when the Media Receiver is not connected with the PDP Note The special communication device for the PDP 503P cannot be used with this unit because the control lines within the MDR cable are different GGF1475 special communication device D SUB 9 pin straight cable PC for control Connect to the D SUB 9 pin connector Communication line Connect the system cable 1 Connection Schem...

Страница 43: ...ns STX start condition 0x02 ETX stop condition 0x03 7 ID setting No ID setting corresponding to all ASCII codes 7 Acknowledgement ACK Acknowledgement ACK will be sent back when the unit returns to Standby mode for the next command after the process of the received command is finished The return data will be a received command in capital letters but without an ID 2 Command format Example of communi...

Страница 44: ...xample of communication MR External PC Returns from the PDP STX 0x02 ETX 0x03 ID Command CPD STX 0x02 ETX 0x03 Command CPD Example of communication MR External PC If the adjustment value of the received command is out of the adjustable range XXX will be sent back and the adjustment value will not be changed If the adjustment value of the received command is the same as the current adjustment value...

Страница 45: ...ing Power Consumption mode to 4 split normal curve S01 POWER CONTROL MODE1 Setting Power Consumption mode to 2 split normal curve S02 POWER CONTROL MODE2 Setting Power Consumption mode to 2 split power saving curve S10 POWER CONTROL NORMAL Setting Power Consumption mode to 4 split normal curve domestic S11 POWER CONTROL MODE1 Setting Power Consumption mode to 2 split normal curve domestic S12 POWE...

Страница 46: ...ck raster S25 MASK SINGLE 25 Window Hi 870Lo 102 PATTAN3 S26 MASK SINGLE 26 Window Hi 1023Lo 102 PATTAN3 S27 MASK SINGLE 27 Window Hi 1023 Pattern 3 S28 MASK SINGLE 28 Window Hi 1023 4 Pattern 3 S29 MASK SINGLE 29 Window Hi 1023 1 25 Pattern 3 S30 MASK SINGLE 30 Window 1 7LINE Pattern 3 S51 MASK SINGLE 51 Raster White S52 MASK SINGLE 52 Raster Red S53 MASK SINGLE 53 Raster Green S54 MASK SINGLE 54...

Страница 47: ... input signal data QPD QUEST POWER DOWN Acquiring logs of power down points QPM QUEST PULSE METER Acquiring data of the pulse meter QPW QUEST PANEL WHITE BALANCE Acquiring panel white balance adjustment values QS1 QUEST STATUS 1 Acquiring data on the unit such as the version of the program QS2 QUEST STATUS 2 Acquiring data on the status of the unit such as temperature QSD QUEST SHUT DOWN Acquiring...

Страница 48: ... the frequency in Mask mode to VD 50 Hz S03 FREQENCY VIDEO 60Hz Setting the frequency in Mask mode to VD 60 Hz S05 FREQENCY THEATER 72Hz Setting the frequency in Mask mode to VD 72 Hz S06 FREQENCY 75Hz Setting the frequency in Mask mode to VD 75 Hz S13 FREQENCY PC 60Hz Setting the frequency in Mask mode to PC 60 Hz S14 FREQENCY PC 70Hz Setting the frequency in Mask mode to PC 70 Hz S22 FREQENCY VI...

Страница 49: ...yte 001AM space 3 10 SQ VIDEO 43 42 4Byte 001X 11 SQ PC 43 42 4Byte 001X 12 SQ VIDEO 50 61 4Byte 001W 13 SQ PC 50 61 4Byte 001W CS 2Byte 7B SEQUENCE Data 8Byte 1st 3rd characters Num For representing the version in 3 digit decimal 4th character W When the sequence data are only for 50 X When the sequence data are only for 43 Product type S System model MDUcom SEQUENCE PROCESSOR PRG 8Byte 1st chara...

Страница 50: ...ta PD data 0 No PD data 1 Not used 2 POWER 3 SCAN 4 SCN 5V 5 Not used 6 Y DCDC 7 Y SUS 8 ADRS 9 X DRV A X DCDC B X SUS C Not used D SQ IC E Not used F Specification inability SD main data 0 No SD 1 SQ IC 2 MDU IIC 3 RST2 4 Panel having high temperature 5 Short circuited speaker Operation status induced by SD 0 Normal 1 Relay off completed 2 During warning indication MASK indication 0 MASK OFF 1 MA...

Страница 51: ...1Byte 0 11 B RIVISE setting value 1Byte 0 CS 2Byte B7 Command Format Effective Operation Modes Function Remarks QIP All operations To acquire data on operations of the panel Return data 3 ECO 39 DATA 2 CS 44Byte 7 Acquisition of other data on the panel QIP The command QIP is for acquiring data other than those available with QS1 data necessary before turning the power on and QS2 data to inform of ...

Страница 52: ...ting n 0 to F Transition of brightness by protective operations 0 Upper limit state for brightness 1 Brightness being reduced 2 Lower limit state for brightness 3 Brightness being increased The output data on the accumulated number of pulses for each block are calculated in the following way the high order 4 bytes of the accumulated number of pulses for each block are converted into a decimal numb...

Страница 53: ... meter for the fifth latest PD 8byte 00000715 16 Sixth latest 1st PD data 1byte A 17 Sixth latest 2nd PD data 1byte 2 18 Data from the hour meter for the sixth latest PD 8byte 00000552 19 Seventh latest 1st PD data 1byte A 20 Seventh latest 2nd PD data 1byte 0 21 Data from the hour meter for the seventh latest PD 8byte 00000213 22 Eighth latest 1st PD data 1byte D 23 Eighth latest 2nd PD data 1byt...

Страница 54: ... hour meter for the fifth latest SD 8byte 00000852 16 Sixth latest SD data 1byte 2 17 Sixth latest SD subcategory data 1byte 5 18 Data from the hour meter for the sixth latest SD 8byte 000000451 19 Seventh latest SD data 1byte 0 20 Seventh latest SD subcategory data 1byte 0 21 Data from the hour meter for the seventh latest SD 8byte 00000000 22 Eighth latest SD data 1byte 0 23 Eighth latest SD sub...

Страница 55: ...tection 1byte 1 21 Result of detection for external protection 1byte 1 22 Transition of protection operation 1byte 0 23 Reservation 4byte CS 2Byte 27 If data for an item cannot be obtained during Standby mode the return data for that item will be The types of data for Items 1 3 in the table drive sequence standard nonstandard and type of ABL WB tables are the same as with the command QPW Each tota...

Страница 56: ...ing while Mask is ON Setting while Mask is OFF Remarks Detection of still picture OFF ON Detection of cracking in the panel OFF ON Scanning protection OFF ON 7 Setting for Factory mode permission prohibition FAY FAN PFY PFN The commands FAY FAN and PFY PFN are for prohibiting permitting panel adjustment commands during normal operation and are to be used to avoid accidental change of panel adjustm...

Страница 57: ...t values When the flag indicating that the line adjustments SUS waveform voltage margin and panel WB for the main unit have been completed is set to on data stored from Addresses 0x0000 to 0X00FF in the digital EEPROM are copied to the same addresses of the backup EEPROM Copying will be executed immediately before the relay of normal operation is off When the command BCP is received while a warnin...

Страница 58: ...t Enter VOF112 Reference adjustment of the Vyprst voltage Ex 50 inch Vyprst 270 V Check the conversion chart Enter VRP055 Note that the conversion charts for 50 inch and 43 inch Panels are different Clearing data on various histories of the Panel such as those on the hour meter It is necessary to clear the data on the hour meter etc to match them to the actual driving hours of the Panel It is also...

Страница 59: ...59 86 VOF022 18 20 VOF078 28 66 VOF134 39 12 VOF190 49 58 VOF246 60 04 VOF023 18 39 VOF079 28 85 VOF135 39 31 VOF191 49 77 VOF247 60 23 VOF024 18 57 VOF080 29 03 VOF136 39 49 VOF192 49 96 VOF248 60 42 VOF025 18 76 VOF081 29 22 VOF137 39 68 VOF193 50 14 VOF249 60 60 VOF026 18 95 VOF082 29 41 VOF138 39 87 VOF194 50 33 VOF250 60 79 VOF027 19 13 VOF083 29 59 VOF139 40 05 VOF195 50 52 VOF251 60 98 VOF0...

Страница 60: ...81 0 271 0 VRP136 305 3 295 3 VRP025 257 1 247 1 VRP081 281 5 271 5 VRP137 305 8 295 8 VRP026 257 6 247 6 VRP082 281 9 271 9 VRP138 306 2 296 2 VRP027 258 0 248 0 VRP083 282 3 272 3 VRP139 306 7 296 7 VRP028 258 4 248 4 VRP084 282 8 272 8 VRP140 307 1 297 1 VRP029 258 9 248 9 VRP085 283 2 273 2 VRP141 307 5 297 5 VRP030 259 3 249 3 VRP086 283 6 273 6 VRP142 308 0 298 0 VRP031 259 7 249 7 VRP087 28...

Страница 61: ... 316 6 VRP241 351 0 341 0 VRP186 327 1 317 1 VRP242 351 4 341 4 VRP187 327 5 317 5 VRP243 351 8 341 8 VRP188 327 9 317 9 VRP244 352 3 342 3 VRP189 328 4 318 4 VRP245 352 7 342 7 VRP190 328 8 318 8 VRP246 353 1 343 1 VRP191 329 2 319 2 VRP247 353 6 343 6 VRP192 329 7 319 7 VRP248 354 0 344 0 VRP193 330 1 320 1 VRP249 354 4 344 4 VRP194 330 5 320 5 VRP250 354 9 344 9 VRP195 331 0 321 0 VRP251 355 3 ...

Страница 62: ... 7 1 DIAGNOSIS 7 1 1 PCB LOCATION POWER SUPPLY Unit SUS CLAMP 1 Assy 50 Y DRIVE Assy 50 SCAN B Assy 50 SCAN A Assy HD LED Assy HD AUDIO Assy HD DIGITAL Assy SUS CLAMP 2 Assy HD IR Assy 50 ADDRESS Assy 50 ADDRESS Assy 50 ADDRESS Assy 50 ADDRESS Assy 50 X DRIVE Assy ...

Страница 63: ...en the power will be shut off When a shutdown or power down occurs on the Panel side the Media Receiver will enter Standby mode the red LED will light Standby Status LED Pattern Power ON AC Power OFF of one side System cable disconnection Power down Shutdown No backup copy Operation statuses indicated by LEDs PD power down count 1000ms 1000ms 500ms 200ms 500ms Once Once Once Twice Once Twice 1000m...

Страница 64: ...C HD AUDIO Assy IC3753 IC3001 3 times Power failure of the driving processor RST2 HD DIGITAL Defective DC DC converter DIGITAL DD CON BLOCK U3601 Check if 3 3 V and 1 2 V power supplies are activated Check if the 8 V power is supplied at Pin 1 of the D11 connector Defective RST IC PANEL FLASH BLOCK IC3302 IC3304 Defective IC3401 SQ ASIC BLOCK IC3401 POWER SUPPLY The 8 V power supply is not activat...

Страница 65: ...tected CN2401 CN2402 IC5V UVP SCAN IC SCAN IC 50 43 Y DRIVE IC5V DC DC Q2605 R2647 Y SUS BLOCK R2352 6 Y DCDC 50 43 Y DRIVE VOFS UVP VOFS DC DC Q2606 R2619 R2620 Y SUS BLOCK IC2252 IC2253 Q2280 Q2281 MSKS SUSOUT short circuit Vprst UVP Vprst Regulator Q2531 Q2532 IC2535 7 Y SUS 50 43 Y DRIVE Power down caused by detection of middle point voltage Y RESONANCE BLOCK IC2101 Y SUS BLOCK Q2221 8 ADRS 50...

Страница 66: ... _ _ _ _ _ 0 A 2 T I O N I N 1 5 2 0 6 0 R G B H E S 6 F A C T 1 5 10 15 16 1 5 10 15 20 25 30 32 1 2 3 4 5 6 7 8 9 A B C D E AREA Note With this model the structure of Factory mode has been changed and all items related to the Panel are gathered into PANEL FACTORY mode Note On screen displays in Factory mode are indicated in white characters on a green background for the PDP 506HD 436HD and subse...

Страница 67: ...valent to PRL 6 5 G LOW 000 to 999 Equivalent to PGL 6 6 B LOW 000 to 999 Equivalent to PBL 6 7 ABL 000 to 255 Equivalent to ABL 7 PANEL REVISE 7 1 R LEVEL LV 0 to LV 7 Equivalent to RRL 7 2 G LEVEL LV 0 to LV 7 Equivalent to RGL 7 3 B LEVEL LV 0 to LV 7 Equivalent to RBL 8 ETC 8 1 BACKUP DATA NO OPRT TRANSFER or ERR Equivalent to BCP 8 2 DIGITAL EEPROM NO OPRT DELETE REPAIR Equivalent to FAJ UAJ ...

Страница 68: ... OFF L R Updating displayed information A P N E L A P N E L N I F O R A M O M D U L E 0 1 M S 0 S 1 E S Q P G R 0 1 M A Q S D T V 5 2 0 W Q S D T P 5 2 0 W I D G E P E A D J S U T D E A B C K U P N O A D T A E S R I A L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 0 A 2 T I O N I N 1 5 2 0 6 0 R G B H E S 6 F A C T 1 5 10 15 16 1 5 10 15 20 25 30 32 2 PANEL WORKS A P N E L A P N E L O W R K S M P B 1 0 0 0 0 0 M...

Страница 69: ...bility UNKNOW 4 SHUT DOWN Basically data acquired with the command QSD for MDU IIC subcategory data are also displayed are displayed with the values from the hour meter when the shutdown occurred Causes of shutdown and corresponding OSD indications A P N E L H S U T O D W A M I N U S B N 1 4 2 0 0 0 1 2 A U D O I T E M 1 P O M 3 M D I I C E E P R 4 5 7 S Q C I V O L I C 8 6 M D I I C H 2 3 M 1 4 2...

Страница 70: ...MASK ON OFF A P N E L L 1 B T 6 0 V S I N 1 5 2 0 6 0 R G B H E S 6 F A C T X S U S B A J P N E L 1 A D 2 1 8 1 5 10 15 16 1 5 10 15 20 25 30 32 Type of WB ABL Tables Type of Drive Sequences Standard Video MASK ON Nonstandard Video PC TBL1 48VS 60PS Not used for consumer products TBL2 50VS 50VN 70PS TBL3 60VS 60VN TBL4 72VS Only Mask indication 75VS 75VN No Items Adjustment Setting Value Remarks 1...

Страница 71: ...3 B HIGH 000 to 511 Equivalent to PBH 4 R LOW 000 to 999 Equivalent to PRL 5 G LOW 000 to 999 Equivalent to PGL 6 B LOW 000 to 999 Equivalent to PBL 7 ABL 000 to 255 Equivalent to ABL DOWN Shifting to the next item UP Shifting to the previous item RIGHT Adding by one to the adjustment value LEFT Subtracting by one from the adjustment value VOL Adding by 10 to the adjustment value VOL Subtracting b...

Страница 72: ...rks 1 R LEVEL LV 0 to LV 7 Equivalent to RRL 2 G LEVEL LV 0 to LV 7 Equivalent to RGL 3 B LEVEL LV 0 to LV 7 Equivalent to RBL DOWN Shifting to ETC UP Shifting to PANEL 2 ADJ SEL MASK ON OFF SET Shifting to the next nested layer 7 Key operation DOWN Shifting to the next item UP Shifting to the previous item RIGHT Adding by one to the adjustment value LEFT Subtracting by one from the adjustment val...

Страница 73: ...on DOWN Shifting to the next item UP Shifting to the previous item RIGHT Adding by one to the adjustment value LEFT Subtracting by one from the adjustment value SET Determining the setting value and shifting to the upper layer SEL MASK ON OFF 7 Key operation No Items Adjustment Setting Value Remarks 1 BACKUP DATA NO OPRT TRANSFER ERR is indicated when no data are in the backup EEPROM To activate t...

Страница 74: ... V 0 1 5 10 15 16 1 5 10 15 20 25 30 32 No Items Adjustment Setting Value Remarks 1 MASK OFF Equivalent to MKS S00 2 SGL MASK 01 48V 50V 60V 60P 70P 72V 75V Equivalent to MKS S01 3 SGL MASK 02 Equivalent to MKS S02 4 5 CMB MASK 09 Equivalent to MKC S08 6 CMB MASK 10 Equivalent to MKC S09 DOWN Shifting to PANEL INFORMATION UP Shifting to ETC SEL MASK ON OFF SET Shifting to the next nested layer 7 K...

Страница 75: ...e being input with only the DVI connecter connected After a warning is displayed for about 5 seconds the unit is ready to display the screen of the input signal Blue LED lit Notes Although the output from XGA 43 inch and WXGA 50 inch can be input to the unit this is not a mode open to general users With some signals errors such as power down may occur As the connection conditions of the system cab...

Страница 76: ...mand for turning the function off DRV S01 Notes When the power to the large signal system is off as the PD signal is muted power downs other than PS_PD are not activated As soon as the clips are removed while the power to the large signal system is off a power down will occur Be sure to turn the power off before removing the clips While this function is activated with RS 232C commands it is possib...

Страница 77: ...ustment data set at the factory are stored in the EEPROM IC 4K on the HD DIGITAL Assy Those adjustment data are automatically backed up in the EEPROM backup EEPROM IC on the HD AUDIO Assy Therefore even if the HD DIGITAL Assy is replaced the adjustment data can be restored by copying the backup data which enables you to omit newly performing adjustments on the main unit Data to be backed up Voltag...

Страница 78: ...placed with one for servicing because of a defective EEPROM on the original Assy and manual adjustments are to be performed In a case where no data are stored in the HD DIGITAL Assy or as backup and the values that have been manually adjusted on Service Menu are to be applied as adjustment data for the main unit Command UAJ Effective during FAY Factory Menu PANEL INFORMATION down down ETC set BACK...

Страница 79: ...red 2 To clear data using RS 232C commands after entering Factory mode by sending FAY or PFY issue a corresponding command Otherwise the command will not be executed Item Backed up data Type of servicing RS 232C command Panel replacement Replacement of the power supply block Others Hour meter Accumulated display To be cleared Not to be cleared Not to be cleared CHM SD history Point where an SD occ...

Страница 80: ...earing the data on the hour meter HR MTR INFO NO OPRT HR MTR INFO CLEAR right set Press and hold for 5 seconds Clearing the data on the pulse meter down PM B1 BS INFO NO OPRT PM B1 BS INFO CLEAR right set Press and hold for 5 seconds Clearing the data on the number of power ons P COUNT INFO NO OPRT P COUNT INFO CLEAR right set Press and hold for 5 seconds A P N E L L 1 B T 6 0 V S V D 1 1 1 1 6 0 ...

Страница 81: ...common Rear case 506 Control plate HD AUDIO Assy HD DIGITAL Assy 1 5 5 1 5 4 6 2 4 2 2 2 3 3 3 3 3 3 3 3 3 3 2 2 2 3 3 3 2 2 2 2 2 1 1 3 1 Note 1 When reassembling first secure the screws for these holes to position the rear case 506 correctly The hole of a left side the screw tighten the hole of the right side next first 1 Remove the two screws 2 Remove the two screws 3 Remove the two hexagon hea...

Страница 82: ...en the front case assy 506PE is to be reattached The front case assy 506PE can be removed without removing the rear case 506 beforehand Remove the two screws and four screw rivets shown below OK NG 1 Hook the upper part of the Front Case Assy 506PE on the upper part of the Front Panel leaving a fist sized gap between the bottom and the lower part of the Front Case Assy 2 Push the couplers of the F...

Страница 83: ... V2 50 s Unhook the six hooks 3 Release the housing wire 4 Remove the four screws 5 Remove the front chassis VR 50 6 Remove the two screws 7 Remove the two screws 8 Unhook the two PCB spacers 9 Remove the SUS CLAMP 1 and 2 Assys SUS CLAMP 1 and 2 Assys 5 3 2 1 5 2 5 3 6 9 9 8 8 6 7 7 2 3 2 1 1 1 Front chassis H Assy 50 Panel holder V1 50 Hook 3 Front chassis VR 50 Hook 3 SUS CLAMP 2 Assy SUS CLAMP...

Страница 84: ... the three screws 5 Remove the front chassis VL 50 6 Remove the four screws 7 Disconnect the two pin connectors 8 Unhook the seven PCB spacers 9 Remove the 50 SCAN A and B Assys 50 SCAN A and B Assys 6 1 2 2 3 1 Panel holder V1 50 Hook 3 Hook 3 Panel holder V2 50 5 Front chassis VL 50 4 4 4 50 Y DRIVE Assy 50 SCAN B Assy 50 SCAN A Assy 7 7 8 8 8 8 2 2 2 2 6 6 9 9 8 ...

Страница 85: ...OUT59 72 OUT58 71 OUT57 70 OUT56 69 OUT55 68 OUT54 67 OUT53 66 OUT52 65 OUT51 64 OUT50 63 OUT49 62 OUT48 61 OUT47 60 OUT46 59 OUT45 58 OUT44 57 OUT43 56 OUT42 55 OUT41 54 OUT40 53 OUT39 52 OUT38 51 OUT2 100 OUT1 99 N C 98 V DDH 97 V DDH 96 N C 95 GND1 94 GND1 93 CLR 92 SI 91 OC2 90 OC1 89 V DD 88 LAT 87 CLK 86 SO 85 DIR 84 GND1 83 GND1 82 N C 81 V DDH 80 V DDH 79 N C 78 OUT64 77 OUT63 76 26 OUT28 ...

Страница 86: ...ly 81 N C Not connected 82 83 GND1 Ground 84 DIR I Setup of shift register shift direction L Shift into reverse SO SI H Shift forward SI SO 85 SO I O Serial data input output 86 CLK I Serial clock input Fetch SI or SO data to shift register by CLK rise edge 87 LAT I LAT data input L Transfer shift register data to output latch H Hold data to output latch 88 VDD Logic supply 89 OC1 I Output control...

Страница 87: ...angement Top view Block Diagram Truth Table IN B A B Y L L L L H L H L L H H H 1 IN A 2 GND VCC OUT Y 3 5 4 TC74VHC00FTS1 50 X DRIVE ASSY IC1002 Quad 2 Input NAND Gate Block Diagram Truth Table 1A 1 Vcc 14 1B 2 4B 13 1Y 3 4A 12 2A 4 4Y 11 2B 5 3B 10 2Y 6 3A 9 GND 7 3Y 8 A B Y L L H L H H H L H H H L ...

Страница 88: ...V 22 Delay Circuit Driver 43 PSUS 42 PSUS 41 PSUS 40 PSUS 39 PSUS 38 PSUS 33 PSUS 32 PSUS 31 PSUS 30 PSUS 29 PSUS 28 PSUS 27 SUBGND 24 SUBGND 23 SUS MSK 26 AXF1142 50 X DRIVE ASSY IC1101 50 Y DRIVE ASSY IC2101 DK Module Block Diagram PC PL D 3 PL U 10 SUSOUT 15 SUSOUT 16 SUSOUT 17 SUSOUT 18 PL U 11 PL U 12 PL U 13 PD U 8 PC 4 PC 5 PC 6 41 PL D 40 PL D 39 PL D 38 CO D 36 CI D 15V Driver Delay Circu...

Страница 89: ... 9 3A 8 3Y A B Y L L L L H L H L L H H H AXF1141 50 Y DRIVE ASSY IC2252 IC2253 Y Mask Module Block Diagram SUSOUT 1 SUSOUT 2 SUSOUT 3 SUSOUT 4 SUSGND 7 SUSGND 6 SUSGND 8 SUSGND 9 SUSGND 10 VSUS 13 VSUS 12 VSUS 14 VSUS 15 VSUS GND 18 SUS G 19 SUS B 20 5V 21 15V 22 Delay Circuit Driver PSUS 33 PSUS 32 PSUS 31 PSUS 37 PSUS 38 PSUS 39 PSUS 40 PSUS 36 PSUS 30 PSUS 29 SUBGND 24 SUBGND 23 MSK S 27 MSK S ...

Страница 90: ...Diagram Pin Function AO1 1 AO2 2 AO3 3 AO4 GND SDA SCL VCC 4 8 7 6 5 1A 1 Vcc 16 1B 2 1Rx Cx 15 1CLR 3 1Cx 14 1Q 4 1Q 13 2Q 5 2Q 12 2Cx 6 2CLR 11 2Rx Cx 7 2B 10 GND 8 2A 9 8 8bit Latch 8bit Upper Segment R 2R 2 8bit Latch 8bit Upper Segment R 2R 3 7 6 8bit Latch 8bit Upper Segment R 2R 4 5 No Pin Name Pin Function 1 AO1 8 bit resolution D A converter output 2 AO2 3 AO3 4 AO4 5 GND Ground 6 SDA Ser...

Страница 91: ...t Electrostatic protection element 2 PST3610UR HD DIGITAL ASSY IC3304 Reset IC Pin Arrangement Top view Block Diagram Pin Function GND 1 VDD CD OUT 2 4 3 1 4 3 No Pin Name Pin Function 1 GND Ground 2 VDD Power supply Voltage detection 3 CD Capacitor connect pin for delay 4 OUT Reset signal output ...

Страница 92: ...1 CSCS_N2 CSIOSCK1 CSIORXD EXA15 EXA19 CSCS_N0 GND33 TCRAM_MONITOR0 TCRAM_MONITOR1 EXA14 EXA18 UARTRXD VDD33 TCRAM_MONITOR2 CSIORQ EXA13 EXA17 UARTTXD CS10TXD RESETX SDIJTAG EXA12 CSEXWAIT_N SDITRST_N SDITCK SDIDBI_N SDITMS GND12 SDITDO SDITDI GPI000 GPI001 GPI002 CSRD_N CLKS VSSPB VCCPB LPFMONI VCCPA CLK_MONI EXDI014 EXDI07 EXDI015 EXDI04 EXDI012 EXDI05 EXDI013 EXDI06 GND33 VDD33 EXDI02 EXDI010 E...

Страница 93: ...SDA 19 VREFIN 24 SCL 20 VREFOUT 23 GND 21 V 22 INa AGC 12 CVO 25 32 AGC VOL1 VOL2 Logic Bias VOL2 VOL2 TONE INb 31 VOL1 TONE WOW Simulated FOCUS TruBass SRS 3D Tone Ha TONE Hb TONE Lb FCSFIL1b FCSFIL2b SRSFIL1 SRSFIL2 LPF1 LPF2 LPFOUT RECFIL OUTb 14 Tone La 15 29 28 FCSFIL1a 9 FCSFIL2a 10 TBFIL1 2 TBFIL2 1 TBFIL3 42 TBFIL4 41 TBFIL5 40 TBFIL6 39 TBFIL7 38 34 33 7 36 5 4 3 37 27 OUTw 6 VREFIN 24 VR...

Страница 94: ...POWER ON indicator 4 5 6 7 8 AC IN terminal 4 2 3 1 SYSTEM CABLE WHITE BLACK SYSTEM CABLE WHITE BLACK 5 6 7 8 SYSTEM CABLE terminal BLACK SPEAKER right left terminals SYSTEM CABLE terminal WHITE STANDBY indicator POWER button Remote control sensor Front view Rear view ...

Страница 95: ...PDP 506PE 95 5 6 7 8 5 6 7 8 C D F A B E ...

Страница 96: ...PDP 506PE 96 1 2 3 4 1 2 3 4 C D F A B E Jigs list Jig No Jig Name Remarks GGF1475 Special Communication Device See to 6 2 RS 232C COMMAND ...

Отзывы: