PDP-LX5080D
157
5
6
7
8
5
6
7
8
C
D
F
A
B
E
9.3.12 QSI (INPUT SIGNAL DATA)
9.3.13 DRV (PANEL DRIVE-POWER ON / OFF)
Data Arrangement
Data
Length
Output Example
ECO
3 Byte
QSI
1
Type of drive sequence
3 Byte
60V
2
Standard/nonstandard
1 Byte
S
3
Type of ABL/WB tables
2 Byte
T1
4
Total value of PCN
4 Byte
0256
5
Total value of PRH
4 Byte
0256
6
Total value of PGH
4 Byte
0256
7
Total value of PBH
4 Byte
0256
8
Total value of PBR
4 Byte
0512
9
Total value of PRL
4 Byte
0512
10
Total value of PGL
4 Byte
0512
11
Total value of PBL
4 Byte
0512
12
Total value of ABL
3 Byte
128
13
Detection of V frequency
4 Byte
6002
14
Reserved
1 Byte
∗
15
Reserved
3 Byte
∗∗∗
16
Obtained APL data
4 Byte
1023
17
Number of SUS pulses
4 Byte
0457
18
Result of detection of still picture
1 Byte
1
19
Result of detection of cracking in the panel
1 Byte
1
20
Result of detection for scanning protection
1 Byte
1
21
Result of detection for external protection
1 Byte
1
22
Transition of protection operation
1 Byte
0
23
Reserved
4 Byte
∗∗∗∗
CS
2 Byte
27
Command
Format
Effective Operation
Modes
Function
Remarks
[QSI]
All operations
To acquire all data on input video signals
Return data: 3 (ECO) + 66 (DATA) + 2 (CS) = 71 Byte
The command QSI is for acquiring all data on input video signals.
At standby mode, when 10 seconds passed after
issuing [DR
V
+S00], command becomes invalid.
Command
Format
Effective Operation
Modes
Function
Remarks
[DR
V
+S00]
Every time
DRI
V
E OFF
[DR
V
+S01]
Every time
DRI
V
E O
N
(default)
Drive O
N
/OFF: O
N
/OFF control of panel drive-power system
The DRI
V
E OFF status established by the DR
V
S00 command is canceled when the power cord is unplugged, the Main
Power switch is set to OFF, or 10 seconds or more has elapsed without any operation in Standby mode. The DRI
V
E OFF key
on the remote control unit for servicing functions the same as the DR
V
S00 command. (A function equivalent to that of the
DR
V
S01 command [DRI
V
E O
N
] is not available with the remote control unit for servicing.)
Содержание KURO PDP-LX508D
Страница 19: ...PDP LX5080D 19 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 20: ...PDP LX5080D 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Страница 22: ...PDP LX5080D 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Страница 23: ...PDP LX5080D 23 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 159: ...PDP LX5080D 159 5 6 7 8 5 6 7 8 C D F A B E ...
Страница 170: ...PDP LX5080D 170 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...