No.
Submode Name
Adjustable Range
Remarks
Submode Items
1
PANEL INFORMATION
2
PANEL WORKS
3
POWER DOWN
4
SHUT DOWN
5
PANEL-1 ADJ (+)
5-1
X-SUS B <=>
120 to 136
Equivalent to XSB
5-2
Y-SUS B <=>
120 to 136
Equivalent to YSB
5-3
Y-SUSTAIL T <=>
120 to 136
Equivalent to YTG
5-4
Y-SUSTAIL W <=>
120 to 136
Equivalent to YTW
5-5
XY-RST W <=>
120 to 136
Equivalent to RSW
5-6
VOL SUS <=>
000 to 255
Equivalent to VSU
5-7
VOL OFFSET <=>
000 to 255
Equivalent to VOF
5-8
VOL RST P <=>
000 to 255
Equivalent to VRP
5-9
SUS FREQ. <=>
MODE1 to MODE8
Equivalent to SFR
6
PANEL-2 ADJ (+)
6-1
R-HIGH <=>
000 to 511
Equivalent to PRH
6-2
G-HIGH <=>
000 to 511
Equivalent to PGH
6-3
B-HIGH <=>
000 to 511
Equivalent to PBH
6-4
R-LOW <=>
000 to 999
Equivalent to PRL
6-5
G-LOW <=>
000 to 999
Equivalent to PGL
6-6
B-LOW <=>
000 to 999
Equivalent to PBL
6-7
ABL <=>
000 to 255
Equivalent to ABL
7
PANEL REVISE
7-1
R-LEVEL <=>
LV-0 to LV-7
Equivalent to RRL
7-2
G-LEVEL <=>
LV-0 to LV-7
Equivalent to RGL
7-3
B-LEVEL <=>
LV-0 to LV-7
Equivalent to RBL
8
ETC (+)
8-1
BACKUP DATA <=>
NO OPRT<=>TRANSFER or ERR
Equivalent to BCP
8-2
DIGITAL EEPROM <=>
NO OPRT<=>DELETE/REPAIR
Equivalent to FAJ/UAJ
8-3
PD INFO. <=>
NO OPRT <=>CLEAR
Equivalent to CPD
8-4
SD INFO. <=>
NO OPRT <=>CLEAR
Equivalent to CSD
8-5
HR-MTR INFO. <=>
NO OPRT <=>CLEAR
Equivalent to CHM
8-6
PM/B1-B5 <=>
NO OPRT <=>CLEAR
Equivalent to CPM
8-7
P-COUNT INFO. <=>
NO OPRT <=>CLEAR
Equivalent to CPC
9
MASK SETUP (+)
9-1
MASK OFF
Equivalent to MKS+S00
9-2
SGL MASK 01 <=>
Equivalent to MKS+S01
9-3
SGL MASK 02 <=>
<=>V48<=>V50<=>V60<=>P60<=>P70<=>V72<=>V75<=>
Equivalent to MKS+S02
• • •
• • •
9-62
CMB MASK 08 <=>
Equivalent to MKC+S08
9-63
CMB MASK 09 <=>
Equivalent to MKC+S09
7
Configuration of Panel Factory mode
49