Structure of Layers in Service Factory Mode
INFORMATION mode
1. VERSION (1)
Flash Versions for PANEL system and MAIN system
2. VERSION (2)
Flash Versions for DTV system
3. VERSION (3)
Flash Versions for CCD ucom and HM
4. MAIN NG
SD histories for MAIN (Going Clear model by SET key)
4-1. CLEAR
Select Yes by [
\
] key
\
pushing and hold [SET] key
5. TEMPERATURE
TEMP 1, TEMP2 and FAN mode are displayed
6. HOUR METER
Hour meter and number of Power ON are displayed
6-1. CLEAR
Select Yes by [
\
] key
\
pushing and hold [SET] key
7. HDMI SIGNAL INFO 1
For factory use
8. HDMI SIGNAL INFO 2
Signal info of HDMI are displayed ( Detail are on SM )
9. VDEC SIGNAL INFO
For factory use
10. DTV TUNING STATUS 1
Detail information for DTV is displayed
11. DTV TUNING STATUS 2
Detail information for DTV is displayed
12. DTV TUNING STATUS 3
Detail information for DTV is displayed
13. DTV TV-GUIDE BER
For production line use
14. DEBUG INFO
For factory use
PANEL FACTORY mode
Refer to [PANEL FACTORY MODE]
OPTION
1. EDID WRITE MODE
For factory use
2. ANTENNA MODE
For production line use
3. AFT
For production line use
INITIALIZE
1. SYNC DET (+)
For factory use
2. SG MODE
SG signal from MAIN VDEC (Composite signal is required)
3. SG PATTERN
For factory use
4. SIDE MASK LEVEL(+)
For factory use
4-1. R MASK LEVEL
4-2. G MASK LEVEL
4-3. B MASK LEVEL
5. FINAL SETUP
Set to Factory default settings (it should perform after
5-1. DATA RESET
replacing a MAIN board )
6. HMG/HG SERVICE MODE Information for a USB device is displayed
6-1. MODE SIFT
7. CVT AUTO
For factory use
8. HDMI INTR PO)
For factory use
Quick Reference upon Service Visit
2
Mode transition and structure of layers in Service Factory mode
Structure of Layers in Panel Factory Mode 1
1. PANEL INFORMATION
Version indication of the panel
2. PANEL WORKS
Indications of the accumulated power-on time, pulse-meter
count, and power-on count of the panel
3. POWER DOWN
Indication of the Power-down history
4. SHUT DOWN
Indication of the Shutdown history
5. PANEL-1 ADJ (+)
1. X-SUS B
2. Y-SUS B
3. Y-SUSTAIL T1
4. Y-SUSTAIL T2
Modification not required because these items are basically
5. Y-SUSTAIL W
for factory presetting
6. XY-RST W1
7. XY-RST W2
8. VOL SUS
9. VOL OFFSET
Settings required after replacement of the panel
10. VOL RST P
11. SUS FREQ.
For AM noise prevention (Depending on the mode,
brightness of the screen changes.)
6. PANEL-2 ADJ (+)
1. R-HIGH
2. G-HIGH
3 .B-HIGH
Parameters for the WB adjustment of the panel, which are
4. R-LOW
required during adjustment after panel replacement
5. G-LOW
6. B-LOW
7. ABL
Setting of the power consumption. A setting table is
available for each vertical signal.
To "Structure of Layers in Panel Factory Mode 2"
Structure of Layers in Panel Factory Mode 2
7. PANEL REVISE (+)
R-LEVEL
G-LEVEL
Items for use by engineers
B-LEVEL
8. ETC (+)
1. BACKUP DATA
For transferring backup data (after replacement of
the DIGITAL Assy)
2. DIGITAL EEPROM
To clear data of the digital video
3. PD INFO.
4. SD INFO.
For clearance of data for the corresponding items.
5. HR-MTR INFO.
The clearing method is the same: Select "CLEAR",
6. PM/B1-B5
using [
\
], then hold [SET] pressed for at least 5
7. P COUNT INFO.
seconds. After clearance is completed, {ETC} is
8. MAX TEMP.
automatically selected.
9. RASTER MASK SETUP (+)
1. MASK OFF
2. RST MASK 01
For use while Raster Mask (full mask) is displayed.
• • • • •
Use [
»
] or [
«
] to select the type of mask.
25. RST MASK 24
10. PATTEN MASK SETUP (+)
1. MASK OFF
2. PTN MASK 01
For use while Pattern Mask is displayed. Use [
»
] or
• • • • •
[
«
] to select the type of mask.
40. PTN MASK 39
11. COMBI MASK SETUP (+)
1. MASK OFF
2. CMB MASK 01
For use while Combination Mask is displayed.
• • • • •
Use [
»
] or [
«
] to select the type of mask.
11. CMB MASK 10
INFORMATION mode
1. VERSION (1)
2. VERSION (2), (3)
3. MAIN NG
4. TEMPERATURE
5. HOUR METER
6. HDMI SIGNAL INFO1, 2
7. VDEC SIGNAL INFO 2
8. DTV TUNING STATUS 1, 2, 3
9. DTV TV-GUIDE BER
10. DEBUG INFO
PANEL FACTORY mode
1. PANEL INFORMATION
2. PANEL WORKS
3. POWER DOWN
4. SHUT DOWN
5. PANEL-1 ADJ
6. PANEL-2 ADJ
7. PANEL REVICE
8. ETC.
9. RASTER MASK SETUP
10. PATTEN MASK SETUP
11. COMBI MASK SETUP
INITIALIZE mode
1. SYNC DET
2. SG MODE
3. SG PATTERN
4. SIDE MASK LEVEL
5. FINAL SETUP
6. HMG/HG SERVICE MODE
7. CVT AUTO
8. HDMI INTR POSITION
OPTION mode
1. EDID WRITE MODE
2. ANTENNA MODE
3. AFT
Up
Down
• To shift to another mode, press [MUTING].
• To shift to another item in a specific mode,
press [
»
] or [
«
].
• To shift to the next nested layer below for an
item with a "(+)" indication, press [ENTER].
To return to the next nested layer above,
also press [ENTER].
Mode transition in Service Factory mode
91
PDP4270HD, PDP4271HD, PDP5070HD, PDP5071HD, PRO507PU
PDP6070HD, PDP6071HD, PRO607PU
Содержание Elite PRO-506PU
Страница 2: ......
Страница 8: ... 2 4 SI PG06003 A Warranty Claim Example 8 ...
Страница 14: ...14 Quick Reference G 3 to G 8 Power Down Shut Down Trap Switch Reset Service Remotes ...
Страница 23: ...23 Models PDP433PU PDP503PU Block Diagrams Shut Down Power Down Diagnosis ...
Страница 30: ...30 Models PDP433CMX PDP503CMX PDP4300 PRO800HD HDI PRO1000HD HDI ...
Страница 31: ...31 Block Diagrams Basic Service Factory Mode Shut Down Power Down Diagnosis ...
Страница 48: ...48 Models PDP434CMX PDP504CMX PDP505CMX PDP4304 PDP4314 PDP5004 PDP5014 PRO810HD PRO1010HD ...
Страница 49: ...49 Block Diagrams Operation LED Statuses Power Down Shut Down Diagnosis ...
Страница 59: ...59 Models PDP4350SX PDP5050SX Block Diagrams Operation LED Statuses Shut Down Power Down Diagnosis ...
Страница 72: ...72 Models PDP436PU PDP506PU PRO436PU PRO506PU ...
Страница 73: ...73 Block Diagrams Operation LED Statuses Shut Down Power Down Diagnosis System Reset ...
Страница 82: ...82 Models PDP4270HD PDP4271HD PDP5070HD PDP5071HD PDP6070HD PDP6071HD PRO507PU PRO607PU ...
Страница 83: ...83 Block Diagrams Quick Reference Power Down Shut Down Diagnosis System Reset Power Supply Jumper ...
Страница 87: ...87 Models PDP6070HD PDP6071HD PRO607PU Block Diagrams on the next two pages ...
Страница 99: ...99 Model PDP427CMX PDP507CMX PDP607CMX Block Diagrams Operation LED s Power Down Shut Down Diagnosis ...
Страница 120: ...120 Scan IC Troubleshooting Blue Glue Removal IC Removal ...
Страница 121: ......
Страница 142: ...142 ...