PRO-1010HD
111
5
6
7
8
5
6
7
8
C
D
F
A
B
E
"
∗∗∗
" in the table above represents the adjustment value.
The value of each subitem can be changed using the
2
or
3
key.
3. COMMON-PANEL1
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
C OMMO
X – S U S
: 1 2 8
U 1
< = >
N – P A N E L 1
I N 1 – G 3 2 – R G B – A H M
No.
Function/Display
Content
Adjustable Range
Corresponding 232C
Command
1
X-SUS U1 <=>
:
∗∗∗
Adjustment of X-SUS leading edge pulse U1
XU1
2
X-SUS U2 <=>
:
∗∗∗
Adjustment of X-SUS leading edge pulse U2
XU2
3
X-SUS D1 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D1
XD1
4
X-SUS D2 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D2
XD2
5
Y-SUS U1 <=>
:
∗∗∗
Adjustment of Y-SUS leading edge pulse U1
YU1
6
Y-SUS U2 <=>
:
∗∗∗
Adjustment of Y-SUS leading edge pulse U2
YU2
7
Y-SUS D1 <=>
:
∗∗∗
Adjustment of Y-SUS trailing edge pulse D1
YD1
8
Y-SUS D2 <=>
:
∗∗∗
Adjustment of Y-SUS trailing edge pulse D2
YD2
9
Y-SUS D3 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D3
YD3
10
Y-SUS D4 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D4
YD4
11
VLT-SUS <=>
:
∗∗∗
SUS voltage adjustment
VSU
12
VLT-OFS <=>
:
∗∗∗
OFFSET voltage adjustment
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
000 to 255
000 to 255
VOF
Each time the
5
or
∞
key is pressed, the subitems are changed, as follows:
Notes:
• Adjustments No. 1 to No. 10 above are not normally required, unless so instructed by Service Information, etc.
• Readjustment of values for No. 11 [VSU] and No. 12 [VOF] are required when the service panel is replaced.