DVR-A06
9
5
6
7
8
5
6
7
8
C
D
F
A
B
E
3.1.4 INSPECTION (FAULT ANALYSIS PROGRAM) METHOD
Caution:
Please use in the Real MS-DOS mode. (The program does not work in the MS-DOS prompt (DOS window) of the
Windows.)
• Discs to be used
CD-ROM
: GGV1054
DVD-ROM (Single) : GGV1035
DVD-ROM (Dual)
: GGV1036
CD-R
: GGX1011
CD-RW
: GGV1088
DVD-R
: GGV1049
DVD-RW
: GGV1050
DVD+R
: RICHO
DVD+RW
: RICHO
• Inspection program disc
FA Program Disc: GGS1049
• Installation method
1. Copy the program file "R6a_fa.exe" .
• Execution method
1. Start the PC in the MS-DOS mode.
2. Move to the directory to which the program file has been copied.
Example: CD DVR106 [enter] (For "C:\DVR106")
3. Execute the program.
r6a_fa /sv [enter] : (in case of the Japanese environment)
r6a_fa /e /sv [enter] : (in case of the English environment)
(In case of English environment, it is difficult to see the frame line if command "/e" is not added.)
"OK" or "NG" is displayed here.
• Start-up screen
Operation
Key Operation
To move the window
Right or left cursor keys
To select the measurement item
Up or down cursor keys
To execute the measurement
Enter key
To execute all items continuously
Space key
To quit the program
Esc key
To format CD-RW (full)
F or f key
To format DVD-RW (quickl)
G or g key
To format DVD+RW (Basic)
M or m key
DVR-106 (ATAPI)
for FA (GGS1049)
Ver1.1