DEH-X5600BT/XNEW5
33
5
6
7
8
5
6
7
8
C
D
F
A
B
E
8.3 PCL OUTPUT CONFIRMATION
9. EXPLODED VIEWS AND PARTS LIST
-
PCL Output
In the normal operation mode (with the detachable panel installed, the ACC switched ON, the standby mode
cancelled), shift the TESTIN IC601(Pin 117) terminal to H.
The clock signal is output from the PCL terminal IC601(Pin139).
The frequency of the clock signal is 600 kHz that is divided by 20th of the oscillation frequency of X601 (12MHz).
The clock signal should be 600 kHz(- 25 Hz, + 25 Hz).
If the clock signal is out of the range, the X'tal (X601) should be replaced with new one.
N
OTES : Parts marked by "
*
" are generally unavailable because they are not in our Master Spare Parts List.
The
>
mark found on some component parts indicates the importance of the safety factor of the part.
Therefore, when replacing, be sure to use parts of identical designation.
Screw adjacent to mark on the product are used for disassembly.
For the applying amount of lubricants or glue, follow the instructions in this manual.
(In the case of no amount instructions,apply as you think it appropriate.)
"