29
Lightning 1000 Installation Guide
ShotBox Connection
To connect the optional ShotBox A and ShotBox B:
1.
Connect the supplied 25-foot (7.6 m) RS-422 cable (supplied with
the option) from the chassis RS422-A port to the Control port on
ShotBox A. The configuration of port RS422-A is COM3.
2.
Connect the supplied 25-foot (7.6 m) RS-422 cable (supplied with
the option) from the chassis RS422-B port to the Control port on
ShotBox B. The configuration of port RS422-B is COM4.
The following table provides pinout information for the RS-422-A and RS-
422-B connectors (mini 9-pin “D” Female). Note that these are dif
dif
dif
dif
diffffffer
er
er
er
erent
ent
ent
ent
ent
from the pinouts of ports RS-422-C and RS-422-D.
1
2
3
4
5
6
7
8
9
Pin Signal
Pin
Signal
1
No connection
6
Power Ground
2
Transmit –
7
Tr
3
R
8
Receive –
4
Power Ground
9
Chassis Ground
5
Chassis Ground
GPI Connection
GPI (General Purpose Interface) is a method by which electronic “pulses”
from one device are used to trigger functions on another device.
This section provides instructions for connecting GPI inputs for four
assignable GPI inputs. When an external device such as an automation
system is connected and when remote control is enabled (using the Enable
GPI triggers menu item), external pulses can control specific functions of
the Lightning.
See your automation system’s manual for steps on connecting its GPI lines.
The following table lists GPI input specifications.
Parameter
Specification
Minimum Pulse Width . . . . . . . .5 mS
Action . . . . . . . . . . . . . . . . . . . Pull-down to ground
Current sourcing . . . . . . . . . . . Approximately 5 mA