Pinnacle Climate Technologies REMINGTON REM-18PNCH-B Скачать руководство пользователя страница 1

CONSUMER: READ AND RETAIN THESE INSTRUCTIONS FOR FUTURE USE

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUC-

TIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, 

SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, 

EXPLOSION, BURN. ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR ELECTRIC 

SHOCK. 

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE 

OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS 

AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.

FIRE, BURN, INHALATION, AND EXPLOSION 

HAZARD. KEEP SOLID COMBUSTIBLES,

SUCH AS BUILDING MATERIALS, PAPER OR 

CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS REC-

OMMENDED BY THESE INSTRUCTIONS. NEVER USE THE HEATER 

IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE 

COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, 

PAINT THINNERS, DUST PARTICLES OR UNKNOWN CHEMICALS. 

KEEP ALL COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAM-

MABLE VAPORS AND LIQUID AWAY FROM THIS HEATER.

This heater is designed and approved for use as a construction heater in accordance with 

Standard for Gas fired Construction heaters ANS Z83.7 * CSA 2.14-2017. CHECK WITH YOUR 

LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS. 

Other standards govern the use of fuel gasses and heating products for specific uses. Your 

local authority can advise you about these. 

MODEL NUMBER

REM-18PNCH-B

Factory ID: 525

DANGER

WARNING

Sauk Rapids, MN 56379 USA • Toll Free 

(800) 641-6996

Fax: 320-251-2922 • Web: 

www.remingtonheater.com

 • Email: [email protected]

© 2019 Pinnacle Climate Technologies, Inc.

 

RBCB-40

2

User’s Manual & 

Operating Instructions

CABINET HEATER

Locating Your Serial Number:

Your serial number can be found on the heater’s rating label. It will be 8 digits. For Example: 12345678. 

Have your Serial Number ready before calling customer service at 1-800-641-6996.

Содержание REMINGTON REM-18PNCH-B

Страница 1: ...OLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS KEEP ALL COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAM MABLE VAPORS AND LIQUID AWAY FROM THIS HEATER This heater is designed and appro...

Страница 2: ...can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov EXT...

Страница 3: ...high altitudes FOR INDOOR USE ONLY Adequate ventilation shall be provided in accordance with OSHA 29 CFR 1926 154 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment ANS...

Страница 4: ...pane Installation Codes CSA B149 1 Periodically monitor levels of CO CO and NO existing at the construction site at the minimum at the start of the shift and after 4 hours Provide ventilation air exch...

Страница 5: ...any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural Gas and Propane Inst...

Страница 6: ...t connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly inform dealer where you purchased the heater...

Страница 7: ...e bottom plate and replace the back cover 2 To connect LP cylinder insert regulator end fitting into cylinder valve rotate coupling nut clockwise and tighten firmly see Figure 2 3 Open valve on propan...

Страница 8: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Страница 9: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Страница 10: ...To move the heater release the brakes simply by flipping the levers on both brakes up The gas must be turned off at the propane supply cylinders s when the heater is not in use OPERATION CONT Risk of...

Страница 11: ...nd re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This debris can impair the heaters ability to d...

Страница 12: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Страница 13: ...012 0260 No Part 1 Switch 2 Piezo Ignition 3 Switch Base 4 Top Nut 5 Valve 6 Burner 7 3rd Setting Copper Pipe System 8 1st Setting Copper Pipe System 9 ODS Copper Pipe 10 2nd Setting Copper Pipe Syst...

Страница 14: ...he item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Страница 15: ...Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2019 Pinnacle Climate Technologies Inc...

Страница 16: ...S VOLATILES OU EN SUSPENSION DANS L AIR OU ENCORE DES PRODUITS COMME DE L ESSENCE DES SOLVANTS DES DILUANTS PEINTURE DES PARTICULES DE POUSSI RE OU DES PRODUITS CHIMIQUES INCONNUS GARDER TOUS LES MAT...

Страница 17: ...te chaufferette AVERTISSEMENT CET APPAREIL EST EXTR MEMENT CHAUD PENDANT SON FONCTIONNEMENT Ne toucher aucun composant en m tal pendant le fonctionnement Garder tous les mat riaux combustibles l essen...

Страница 18: ...GE INT RIEUR SEULEMENT Fournir une ventilation ad quate conform ment la norme OSHA 29 CFR 1926 154 aux exigences de s curit pour les appareils et quipements portables de chauffage temporaire la norme...

Страница 19: ...s sur le chantier au minimum au d but du quart de travail et apr s 4 heures Assurer un change d air par une ventilation appropri e naturelle ou m canique afin de maintenir une qualit acceptable de l a...

Страница 20: ...absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 et du Code d installation du propane et du gaz naturel CSA B149 1 V rifier les connexions d alimentation en gaz...

Страница 21: ...e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport Si la chaufferette est endommag e informer imm diatement...

Страница 22: ...capot arri re 2 Raccorder la bouteille de propane ins rer le raccord du r gulateur dans le robinet de la bouteille tourner l crou du raccord dans le sens horaire et le serrer fermement Figure 2 3 Ouvr...

Страница 23: ...e d endommager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soume...

Страница 24: ...tre liquide inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les informations sur la s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de p...

Страница 25: ...Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes Le gaz doit tre coup au niveau du ou des cylindres d alimentation en propane lorsque la chauffere...

Страница 26: ...t s r Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la vent...

Страница 27: ...la bouteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Positio...

Страница 28: ...crou sup rieur 5 Robinet 6 Br leur 7 Syst me de tuyauterie en cuivre troisi me position 8 Syst me de tuyauterie en cuivre premi re position 9 Tuyau de cuivre du capteur d appauvrissement en oxyg ne 10...

Страница 29: ...ion et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dan...

Страница 30: ...Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2019 Pinnacle Climate Technologies Inc...

Отзывы: