40
Sentinel & PimaGuard
Installation Guide
*1 = E, 3 = R (CID depend of rs232 protocol)
NPAF/EPAF
NPAF & EPAF events are the same, until the event “Listen-In To Follow” (Code TR)
False Code
SL
D8
421
1
0
z
A 102
Hold-Up
SM
E3
121
1
0
z
T B
Panic
SN
E4
120
1
0
z
T 9
Fire
SO
E5
110
1
0
z
T B
Temperature
SP
E6
159
1
0
z
S B
Humidity
SQ
E7
150
1
0
z
S B
SR
SR
EB
616
1
0
z
S B
Upload/Download
SS
E9
412
1
0
z
S B
ST
ST
EA
616
1
0
z
C E
Shock Detector
SU
E8
376
1
0
z
X 25
General Alarm
SV
EC
140
1
0
z
X 25
Reset
SW
ED
140
3
0
z
X 25
Test
SX
EE
600
1
0
z
A 100
Arming
SY
EF
400
3
0
z
D
Disarming
SZ
F0
400
1
0
z
A 102
Zone Fault(AntiMask)
TA
F1
616
1
0
z
X 25
Medical Alarm
TB
EC
616
1
0
z
X 25
Silent Panic
TC
E4
616
1
0
z
X 25
Special Fire
TD
E5
616
1
0
z
X 25
TE
TE
FF
616
1
0
z
X 25
TF
TF
FF
616
1
0
z
X 25
TG
TG
FF
616
1
0
z
X 25
TH
TH
FF
616
1
0
z
X 25
TI
TI
FF
616
1
0
z
X 25
TJ
TJ
FF
616
1
0
z
X 25
TK
TK
FF
616
1
0
z
X 25
TL
TL
FF
616
1
0
z
X 25
TM
TM
FF
616
1
0
z
X 25
Repeater Failure
TN
F3
616
1
0
z
X 25
TO
TO
FF
616
1
0
z
X 25
Tamper 2 Alarm
TP
C5
137
1
0
z
X 25
Tamper 2 Restore
TQ
C6
137
3
0
z
X 25
Listen In To Follow
TR
FF
606
1
0
z
X 25
Description
Code
HEX2DGT
CID event
CID alarm*
CID zone\user
ELL
ELL IRCN
Alarm Zone 1
AA
00
130
1
1
B
A 1
Alarm Zone 2
AB
01
130
1
2
4
A 2
Alarm Zone 3
AC
02
130
1
3
9
A 3
Alarm Zone 4
AD
03
130
1
4
9
A 4
Alarm Zone 5
AE
04
130
1
5
E
A 5
Alarm Zone 6
AF
05
130
1
6
6
A 6
Alarm Zone 7
AG
06
130
1
7
5
A 7
Alarm Zone 8
AH
07
130
1
8
4
A 8
Alarm Zone 9
AI
08
130
1
9
4
A 9
Alarm Zone 10
AJ
09
130
1
10
4
A 10
Alarm Zone 11
AK
0A
130
1
11
4
A 11
Alarm Zone 12
AL
0B
130
1
12
4
A 12
Alarm Zone 13
AM
0C
130
1
13
4
A 13
Alarm Zone 14
AN
0D
130
1
14
4
A 14
Alarm Zone 15
AO
0E
130
1
15
4
A 15
Alarm Zone 16
AP
0F
130
1
16
4
A 16
Alarm Zone 17
AQ
10
130
1
17
4
A 16
Alarm Zone 18
AR
11
130
1
18
5
A 16
Alarm Zone 19
AS
12
130
1
19
4
A 16
Alarm Zone 20
AT
13
130
1
20
4
A 16
Alarm Zone 21
AU
14
130
1
21
C
A 16
Alarm Zone 22
AV
15
130
1
22
0
A 16
Alarm Zone 23
AW
16
130
1
23
F
A 16
Alarm Zone 24
AX
17
130
1
24
F
A 16
Alarm Zone 25
AY
18
130
1
25
F
A 16
Alarm Zone 26
AZ
19
130
1
26
0
A 16
Alarm Zone 27
BA
1A
130
1
27
0
A 16
Alarm Zone 28
BB
1B
130
1
28
0
A 16
Alarm Zone 29
BC
1C
130
1
29
0
A 16
Alarm Zone 30
BD
1D
130
1
30
0
A 16
Alarm Zone 31
BE
1E
130
1
31
0
A 16
Alarm Zone 32
BF
1F
130
1
32
0
A 16
Alarm Zone 33
BG
20
130
1
33
C
A 16
Alarm Zone 34
BH
20
130
1
34
C
A 16
Alarm Zone 35
BI
20
130
1
35
D
A 16
Alarm Zone 36
BJ
20
130
1
36
4
A 16
Alarm Zone 37
BK
20
130
1
37
4
A 16
Alarm Zone 38
BL
20
130
1
38
7
A 16
Alarm Zone 39
BM
20
130
1
39
7
A 16
Description
Code
HEX2DGT
CID event CID alarm* CID zone\user ELL ELLIRCN