Key #3: Communication
57
6.8.2.
Local monitoring interval
Set an interval for test reports to the local Monitoring Station.
6.9.
Modem Callback
Set Up to three callback numbers, for the modem that is used to communicate with the COMAX
upload/download software.
When setting call back #1 number, in any attempt to call the control panel's
PSTN no., it will disconnect the call and call the call back number. This is yet
another measure to protect the system from unauthorized access.
6.10.
Private dialer
Set which events will be reported to the end user via the phone. At least one phone number must
be set (in the User menu).
The next table describes the events in the screen.
Char. Event to report
A
All alarm types
A
Anti-mask alarms
1
Special Burglary 1 alarms
2
Special Burglary 2 alarms
P
Panic alarms
F
Fire alarms
D
Duress alarms
M
Medical alarms
O
Open/Close (SMS only): report by SMS messages only when the panel is
armed/disarmed by codes other than user codes - Master, Short, Door, etc.
L
Failures
6.11.
MS 2 Options
Monitoring Station #2 options are the same as Monitoring Station #1 (except for net reporting to
MS2); see section 6.1, on page 50.
6.11.1.
Protocol
By setting Monitoring Station #2 PSTN protocol the control panel will implement “Double Report”.
To report to 2 monitoring stations with 2 separate account numbers, set “S” (“Split Subscriber”)
to “+” in the “Communication Options” menu (see section 6.4, on page 51). In this case, reports
to Monitoring Station #1 will be sent under the first account, and to Monitoring Station #2 under
the second.
6.11.2.
Reports
3
ENTR
ENTR
NEXT
X10
Communication
ENTER/NEXT/END
Private Dialer
ENTER/NEXT/END
AA12PFDMOL
++++++++-+
3
ENTR
ENTR
NEXT
X11
Communication
ENTER/NEXT/END
MS2 Options
ENTER/NEXT/END
AA12PFDMOLTWIR
++++++++++++++.2
MS 2 Protocol
0
0
ENTR