Keypads
PIMA Electronic Systems
7
LED Type
Status
Indication
Orange
Fault
Flashes
Faults exist
Off
No fault exist, or the system is armed.
2.1.4
Operation keys and keypad alarms
Operation keys
Press and hold the keys described in the next table, for the following operations:
Key Operation
1-4 Arm in
Home 1-4
5
Display the zones’ status
6
Enter
Remote Service menu (with a user code)
2
0
Display the service provider and the control panel’s version
*
Turn the chime on/off
Keypad alarms
You can trigger 3 alarms at the keypad:
Panic, Fire, and Medical. When these alarms are
triggered,
FORCE
activates the programmed responses, including triggering the sirens and
reporting the CMS (where relevant), and the contacts.
Alarm
Press & hold
Medical
4 + 6
Fire
7 + 9
Panic
* + #
2.1.5
Keypad settings
To view the
Keypad Settings screen press and hold the menu key .
In this screen you can set the audio-visual parameters of the keypad,
which are
Contrast, Brightness, Keys Backlight, and the Volume of the
buzzer. Each parameter is scaled 0-9. Settings are per keypad.
To change a parameter, do as follows:
1.
Press an arrow key and select a parameter.
2.
Enter a number between 0-9.
3.
Press to save and exit.
Warning: if you set the
buzzer’s
Volume to 0, no alerts will be sounded
from the keypad, including from chime zones.
Silencing the keypad
To silence the keypad’s buzzer (including the chime) and keys completely, press together the
Back/Exit and Enter
keys. Press again to re-activate the buzzer (toggle).
2
Version 1.2 and higher
Содержание CLW532
Страница 1: ...FORCE Advanced Intruder Alarm System User Guide Including the Lite version Version 1 2 X...
Страница 35: ......