PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
9
}
LEDs for
–
Supply voltage/fault
–
Gate closed
–
State of the inputs
–
State of the magnetic guard locking device
}
M12, 8-pin male connector
Function description
U
B
A1
A2
S31
12
22
Power supply
Power/Fault
&
&
Safety Gate
Lock
Receiver
Magnet
Actuator
Input
S21
S11
&
Y32
There is a high signal at safety outputs 12 and 22 if the following occur
simultaneously
:
}
The actuator is within the response range (safety gate closed) and
}
There is a high signal at the inputs S11 and S21 and
}
There is a high signal at the input S31 (control command for magnetic guard locking)
and
}
The holding force of the locking magnet has been tested successfully.
There is a low signal at safety outputs 12 and 22 if
at least
one
of the following conditions
are met:
}
The actuator is outside the response range or
}
There is a low signal at the inputs S11 or S21 or
}
There is a low signal at the input S31 (control command for magnetic guard locking) or
}
The holding force of the locking magnet has not been tested successfully.