Safety checks, maintenance and repair
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 83
11.2
Checks
11.2.1
Regular check
Regular checks can bring to light changes to the plant/machine, safeguards and ambient
conditions.
Pilz recommends that the safety laser scanner be checked every six months.
}
Check the safety laser scanner’s front panel.
– Scratched front panel: Change the safety laser scanner.
In a particularly dirty environment, front panel cleanliness should be checked more
frequently.
}
Check the tightness of the safety laser scanner.
All screws must be tightened to the torque specified in the
.
}
Check the safety function of the safety laser scanner (see
).
11.2.2
Check after plant/machine modification
Check the safety laser scanner each time the plant/machine is modified. Changing the
safety laser scanner or swapping components of the safety laser scanner should also be
regarded as a modification.
You
must
comply with the requirements of the applicable national regulations.
INFORMATION
This inspection may only be carried out by qualified personnel.
which should help you perform the safety
check.
11.3
Maintenance
Other than cleaning the front panel, the safety laser scanner requires no other form of
maintenance.