PSEN opII4H Series
Operating Manual PSEN opII4H Series
1003501-EN-02
39
}
Check the tightness of the safety light grid’s front panel.
All screws must be tightened to the torque specified in the
.
}
Check the safety function of the safety light grid (see
Check the safety function of the
Check after plant/machine modification
Check the safety light grid each time the plant/machine is modified. Changing the safety
light grid or swapping safety light grid components should be regarded as a modification.
The requirements of the applicable national regulations must be observed
absolutely
.
INFORMATION
This inspection may only be carried out by qualified personnel.
which should help you perform the safety
check.
Maintenance
Other than cleaning the lens covers, the safety light grids requires no other form of main-
tenance.
CAUTION!
Improper cleaning agents can damage the safety light grid and lead to mal-
functions
Moist cotton cloths should be used for cleaning.
Avoid using
}
Alcohol,
}
Solvents,
}
Cloths made of wool,
}
Cloths made of synthetic material.
Clean the lens covers during the regular
check of the safety light grid [
.