PSEN cs4.1p/M12
Operating Manual PSEN cs4.1p/M12
1003293-EN-08
| 22
Installation
CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.
}
The safety switch and actuator should be installed opposite each other in parallel.
}
Actuator PSEN cs4.1: Safety switches and actuators should only be secured using M4
screws with a flat head (e.g. M4 cheese-head or pan head screws).
The actuator should be protected from unauthorised removal and from contamination.
Close the mounting holes using the seals provided. The use of seals should be regarded
as equivalent to using permanent fastenings in accordance with Clause 7.2c of
EN ISO 14119.
}
Actuator PSEN cs2.1: Safety switches and actuators should be permanently secured us-
ing M5 safety screws with a flat head (e.g. M5 cheese-head or pan head screws).
}
Torque setting: Please note the information provided under
}
The distance between two safety switches must be maintained (see
).
}
Make sure that the safety switch and actuator cannot be used as an end stop.
}
Please note the installation measures in accordance with EN ISO 14119 for a safety
switch design 4 and with level of coding High.
}
For simpler installation, the mounting brackets (see
}
Please note the permitted bending radii for the cable (see
avoid excessive force on the individual strands.
}
Make sure that the bend protection is not damaged. Such damage can cause the whole
product to fail.
Procedure:
Please note:
Installation is identical for all combinations of safety switch and approved actuators. The
diagram of the actuators PSEN cs4.1 and PSEN cs2.1 represents the other approved actu-
ators.