Mechanical data
774605
774606
774609
Conductor cross section
with screw terminals
1 core flexible
0,2 - 4 mm², 24 - 10 AWG 0,2 - 4 mm², 24 - 10 AWG 0,2 - 4 mm², 24 - 10 AWG
2 core with the same
cross section, flexible
with crimp connectors,
no plastic sleeve
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
2 core with the same
cross section, flexible
without crimp connect-
ors or with TWIN crimp
connectors
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
Torque setting with screw
terminals
0,6 Nm
0,6 Nm
0,6 Nm
Stripping length with
screw terminals
8 mm
8 mm
8 mm
Dimensions
Height
87 mm
87 mm
87 mm
Width
90 mm
90 mm
90 mm
Depth
121 mm
121 mm
121 mm
Weight
750 g
750 g
750 g
Where standards are undated, the 2020-07 latest editions shall apply.
Safety characteristic data
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
–
PL e
Cat. 4
SIL CL 3
2,31E-09
SIL 3
2,03E-06
20
Explanatory notes for the safety-related characteristic data:
}
The SIL CL value in accordance with EN 62061 corresponds to the SIL value in accord-
ance with EN 61508.
}
T
M
is the maximum mission time in accordance with EN ISO 13849-1. The value also ap-
plies as the retest interval in accordance with EN 61508-6 and IEC 61511 and as the
proof test interval and mission time in accordance with EN 62061.
All the units used within a safety function must be considered when calculating the safety
characteristic data.