![Pilz PNOZ V Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/pilz/pnoz-v/pnoz-v_operating-manual_1556829008.webp)
PNOZ V
Operating Manual PNOZ V
21115-EN-07
| 7
Unit features
}
Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous
– 1 safety contact (N/O), delay-on de-energisation
– 1 auxiliary contact (N/C), instantaneous
}
Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Start button
}
Selectable delay time
}
LED display for:
– Supply voltage
– Switch status of the safety contacts
}
See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
}
The circuit is redundant with built-in self-monitoring.
}
The safety function remains effective in the case of a component failure.
}
The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)