PNOZ mc12p
Operating Manual 1003016-EN-03
}
Configurable safety systems PNOZmulti
Страница 1: ...PNOZ mc12p Operating Manual 1003016 EN 03 Configurable safety systems PNOZmulti...
Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...
Страница 3: ...bility 9 3 3 3 Disposal 9 3 3 4 For your safety 9 Section 4 Function description 10 4 1 Functions 10 4 2 Input and output data 10 4 3 Block diagram 11 Section 5 Installation 12 5 1 General installatio...
Страница 4: ...is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates prevent...
Страница 5: ...Introduction Operating Manual PNOZ mc12p 1003016 EN 03 5 INFORMATION This gives advice on applications and provides information on special fea tures...
Страница 6: ...t and 50 Byte Input is 350 s The minimum cycle time is 500 s at the maximum PDO size of 240 Byte Input and 20 Byte Output the inputs and outputs in this case are viewed from the Managing Node 24 virtu...
Страница 7: ...Overview Operating Manual PNOZ mc12p 1003016 EN 03 7 2 3 Front view Legend X1 X2 Ethernet POWERLINK interfaces LED LINK ACT1 LINK ACT2 PWR S E Status Error...
Страница 8: ...System Expansion for details of the base units that can be connected The configurable small control systems PNOZmulti are used for the safety related interrup tion of safety circuits and are designed...
Страница 9: ...d liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the g...
Страница 10: ...ta The data is structured as follows Input area The inputs are defined in the Managing Node and transferred to the PNOZmulti Each input has a number e g input bit 4 of SDO 2100 02 has the number i12 V...
Страница 11: ...Function description Operating Manual PNOZ mc12p 1003016 EN 03 11 4 3 Block diagram Base unit Ethernet POWERLINK...
Страница 12: ...g rail in an upright position so that the earthing springs on the control system are pressed on to the mounting rail The ambient temperature of the PNOZmulti units in the control cabinet must not exce...
Страница 13: ...of 1 PNOZ mc12p to the left of the base unit Connect the base unit and the expansion module as described in the operating instructions for the base units Do not connect a terminator to the last expan...
Страница 14: ...e connection cable and connector must be met Only use standard industrial Ethernet cable and connectors Only use double shielded twisted pair cable and shielded RJ45 connectors indus trial connectors...
Страница 15: ...Controlled Node 3 6 4 Download modified project to the PNOZmulti system As soon as an additional expansion module has been connected to the system the project must be amended using the PNOZmulti Conf...
Страница 16: ...ffic present at X2 Bus connection not available at X2 S E No supply at the bus controller or the bus controller is in a NOT_ACT IVE state If communication with Ethernet POWERLINK is not detected withi...
Страница 17: ...on yes Times Supply interruption before de energisation 20 ms Environmental data Ambient temperature In accordance with the standard EN 60068 2 14 Temperature range 0 60 C Storage temperature In accor...
Страница 18: ...cabinet IP54 Housing IP20 Terminals IP20 Potential isolation Potential isolation between Fieldbus and module voltage Type of potential isolation Functional insulation Rated surge voltage 500 V Mechan...
Страница 19: ...N 03 19 9 Order reference 9 1 Product Product type Features Order No PNOZ mc12p Fieldbus module Ethernet POWERLINK 773 719 9 2 Accessories Terminator jumper Product type Features Order no PNOZmulti bu...
Страница 20: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...