Function description
Operating Manual PIT m4SEU
1004648-EN-02
| 19
}
Allocation of signal outputs to inputs:
Pushbutton
Input
Signal output
Operating mode 1/5
I1
O1
Operating mode 2
I2
O2
Operating mode 3
I3
O3
Operating mode 4
I4
O4
5.3
Configuration of functions
The PIT m4SEU has a DIP switch, which you can use to set the required communication
mode for downloading the Key ID number and the device's switching behaviour
}
after the transponder key is removed and
}
after the voltage reset
.
The communication modes have different functions. These functions are described in the
following subsections:
}
Transmitter-controlled communication mode [
}
Handshake-controlled communication mode [
}
NOTICE
It is essential to note:
– The configuration may only be performed by a competent person.
– The configuration must be performed when the supply voltage is
switched off.
– The configuration is adopted as the device is started up, provided the
switch setting is valid. If not, the device switches to a "Device error"
fault condition.
– During operation, the DIP switch setting is monitored for any change.
If the switch setting is changed during operation, the device switches
to a "Device error" fault condition, remedy:
– The communication mode changes when you change the DIP switch
setting from Pos. [D1]-[D4] to Pos. [D5]-[D8]. In this case you auto-
matically switch to advanced communication mode.
Legend
1
Off
On
DIP switch in OFF position
1
Off
On
DIP switch in ON position
The sliders of the DIP switches are shown in black in the table.