Commissioning
Operating Manual PNOZ s30
1001715-EN-15
51
}
Switch delay
None
}
Max. encoder frequency
3.5 kHz
6.2.7.3
Basic settings for the rotary encoder
Settings for basic configuration 2
Level
Designation
on the display
Description
Settings
1
Basic Parameter
Encoder:
Default
Load?
Select the default settings with
which the basic configuration
menu "
Rotary encoder:
" is to be
called:
- Load: The basic parameters are
loaded. Then it switches to the ba-
sic menu "
Rotary encoder:
".
The basic parameters should al-
ways be loaded when commis-
sioning for the first time.
- Edit: The basic parameters are
not loaded, i.e. all parameters are
retained. The basic menu para-
meters can be changed within the
permitted boundaries.
-Escape: Exits the basic menu.
2
Encoder
Default
TTL differential
Select rotary encoder type
-TTL differential (A, /A, B, /B)
-TTL single ended (A, B)
-HTL differential (A, /A, B, /B)
-HTL single ended (A, B)
-sin/cos 1 Vss (A, /A, B, /B)
-Hiperface (A, /A, B, /B)
2
Standstill
Rel.1 Out 1
Default
100 Hz
Enter standstill frequency
10 mHz to 1.00 kHz
2
v max
Rel.2 Out 2
Default
5.00 kHz
Enter the max. permitted speed
10 mHz to 1.00 MHz