![Pilz 750132 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/pilz/750132/750132_operating-manual_1556722006.webp)
PNOZ s22
Operating Manual PNOZ s22
22170-EN-04
6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The unit meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. The con-
tact expansion module is used to increase the number of instantaneous safety contacts
available on a base unit. Base units are
}
Speed monitor PNOZ s30
}
PNOZmulti Mini base units PNOZ mm0.1p, PNOZ mm0.2p
The max. achievable safety level depends on the base unit. The expansion module may not
exceed this. The safety-related characteristic values stated under safety-related character-
istic data can only be achieved if the base unit also exhibits these values.
The following is deemed improper use in particular
}
Any component, technical or electrical modification to the product,
}
Use of the product outside the areas described in this manual,
}
Use of the product outside the technical details (see
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.