![Pilz 506228 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/pilz/506228/506228_operating-manual_1556396018.webp)
PSEN ma1.3n-20
Operating Manual PSEN ma1.3n-20
22176-EN-09
| 18
The actuator should be secured using a set
screw M3 x 6 mm DIN 319 (supplied with
the device).
Also note the low max. torque setting (see
Adjustment
}
The safety switch may only be used with the corresponding actuator PSEN ma1.3-08 or
PSEN ma1.3-12.
}
Always test the function with a connected evaluation device.
}
The stated operating distances (see
) only apply when the
safety switch and actuator are installed according to the specifications
. Operating distances may deviate if other arrangements are used.
Note the maximum permitted lateral and vertical offset (see
).
Periodic test
}
Carry out a monthly function test on the safety switch and actuator.
}
Always test the function with a connected evaluation device.
}
The safety function may only be checked by qualified personnel.
Dimensions in mm
Safety switch
2
42,6
2
12,5
59,1
36
46,8
130±5
M1
2
M1
2
x1
11