Battery 1 Hot
Battery 1 + 2 Hot
Battery 2 Hot
3-15-16
continued
6.
Aircraft.........................................
Land as soon as possible
Note
The
Battery 1 Hot
and
Battery 2 Hot
warnings are inoperative on aircraft
with lead acid batteries installed.
---------- END -----------
Battery 1
Battery 2
3-15-17
Battery discharge is above 60 Amps or battery voltage is below 22 V or above 30.1 V.
1.
Systems MFD - ELECTRICAL
window........................................
Check GEN 1 or 2 and BAT 1 or 2 current
and voltage
If indications are normal:
2.
BAT 1 or BAT 2 switch................
OFF
If indications are not normal:
3.
Aircraft.........................................
---------- END -----------
Battery 1 Off
Battery 2 Off
3-15-18
1.
BAT 1 or BAT 2 switch................
Check ON. Reset
---------- END -----------
External Power
3-15-19
External power on with GEN 1 and GEN 2 and AV 1 BUS and AV 2 BUS on.
1.
External power unit.....................
Disconnect
---------- END -----------
Section 3 - Emergency Procedures (EASA Approved)
Electrical System Failures
Pilot's Operating Handbook
Report No: 02406
Issue date: Mar 06, 2020
Page 3-15-11
12-C-A15-40-0315-00A-141A-A