25.3
Remove the safety clip and close the circuit breakers:
−
XPNDR 1 (AVIONIC 1 BUS)
−
XPNDR 2 (AVIONIC 2 BUS).
25.4
Remove all the equipment, tools and materials from the work area. Make sure that the work area is
clean.
25.5
Close access panel 21QZ.
25.6
Disconnect the pitot static test set from the left and right static ports and the left and right pitot heads.
25.7
Install the protective covers on the left and right pitot heads.
Requirements after job completion
Required Conditions
Table 6 Required Conditions
Action / Condition
Data module/Technical publication
None
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-34-14-00-00A-903B-A
End of data module