Reference altitude (m)
PFD Altitude display (m)
Thales ESIS altitude
display (m)
L3 ESIS altitude display
(m)
610
613 ± 9
613 ± 8
613 ± 9
1524
1528 ± 12
1528 ± 9
1528 ± 12
3048
3053 ± 24
3053 ± 15
3053 ± 24
4572
4578 ± 34
4578 ± 18
4578 ± 34
6096
6105 ± 40
6105 ± 23
6105 ± 40
9144
9155 ± 55
9155 ± 37
9155 ± 55
10668
10680 ± 62
10680 ± 41
10680 ± 62
20
Slowly adjust the pitot static test set static pressure towards an altitude display of 1400 feet (427 m).
Watch the PFD display.
20.1
When the altitude display is 1550 feet (472 m), make sure that a semi-transparent rectangular box is
shown in the upper right corner of the PFD ADI.
20.2
When the altitude display is 1500 feet (457 m), make sure that an amber MIN is shown in the box.
21
Slowly adjust the pitot static test set static pressure to ambient.
22
Use the pitot static test set to set the following reference vertical speeds. Make sure that the PFD
vertical speed displays and trend vectors are within the limits.
Reference vertical speed (ft/min)
Altitude trend vector
Vertical speed display (ft/min)
2000
↑ 200
2000 ± 100
0
0
0 ± 45
-2000
↓ 200
-2000 ± 100
23
Slowly adjust the pitot static test set static and pitot pressures to ambient.
24
Close Up
24.1
On the maintenance panel, set the AIR/GND switch to GND.
24.2
De-energize the aircraft electrical system, refer to AMM 12-B-24-00-00-00A-901A-A.
24.3
Remove the safety clip and close the circuit breakers:
−
XPNDR 1 (AVIONIC 1 BUS)
−
XPNDR 2 (AVIONIC 2 BUS).
24.4
Remove all the equipment, tools and materials from the work area. Make sure that the work area is
clean.
24.5
Close access panel 21QZ.
24.6
Disconnect the pitot static test set from the left and right static ports and the left and right pitot heads.
24.7
Install the protective covers on the left and right pitot heads.
Requirements after job completion
Required Conditions
Table 6 Required Conditions
Action / Condition
Data module/Technical publication
None
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-34-14-00-00A-903A-A
End of data module
UNCLASSIFIED