9.4.6 - 200/A SERIES PILOT MAINT PRE-REGULATORS R31/A AND R14/A
9.4.6.1 - PILOT DISCONNECTION SERIES 201/A AND PRE-REGULATOR R31/A
Fig. 9.77. 201/A + R31/A series pilot
To disconnect the 201/A pilot, proceed as in tab. 9.155 (see fig. 9.77):
Step Action
1
Disconnect the sensing lines between the 201/A pilot and the regulator by adjusting the fittings (1, 2, 3).
2
Unscrew and remove the fixing screw to remove the 201/A pilot from the regulator.
3
Remove the pipe (20) by adjusting the fittings (4, 5).
4
Unscrew and remove screw (6) to separate pre-regulator R31/A from pilot 201/A.
5
Undo and remove the screw (7) from pilot 201/A.
Tab. 9.154.
LOADING
VENT
DOWNSTREAM SENS-
ING ELEMENT
UPSTREAM
SENSING ELE-
MENT
Содержание REVAL 182
Страница 2: ...2 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR INTRODUCTION REV 00 ...
Страница 4: ...4 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR INTRODUCTION REV 00 ...
Страница 12: ...12 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR INTRODUCTION REV 00 ...
Страница 22: ...22 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR GENERAL INFORMATION REV 00 ...
Страница 32: ...32 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR SAFETY REV 00 ...
Страница 107: ...107 REVAL 182 Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR COMMISSIONING REV 00 EN ...
Страница 111: ...111 REVAL 182 Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR COMMISSIONING REV 00 EN ...
Страница 115: ...115 REVAL 182 Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR COMMISSIONING REV 00 EN ...
Страница 398: ...398 REVAL 182 EN Use maintenance and warning instructions MEDIUM PRESSURE REGULATOR RECOMMENDED SPARE PARTS REV 00 ...
Страница 404: ......