MANUALE TECNICO MT059
TAB. 4 PARTICOLARE PRESA MULTIPLA
TAB. 4 DETAIL OF MULTIPLE TAKE-OFF
TECHNICAL MANUAL MT059
10
The regulator must be installed in the line with the
arrow on the body pointing in the gas flow direction.
It is indispensable for good regulation for the position
of the downstream pressure take-offs and the speed of
the gas at the take-off point to respect the values given
in tables 3 and 4 (positioning) and 5 (speed).
The following are recommended so as to prevent the
accumulation of impurities and condensate in the lines
of the pressure take-offs:
a) the lines themselves must slope down towards the
downstream piping with a slope of about 5-10%;
b) the connectors on the piping must always be welded
on the top of the piping itself and there must be no burr
or inward protrusions in the hole in the piping.
NB.
DO NOT PUT ON/OFF VALVES ON THE IMPUL-
SE TAKE-OFFS
Il regolatore va installato sulla linea orientando la frec-
cia sul corpo nel senso del flusso del gas.
Per ottenere una buona regolazione è indispensabile
che la posizione delle prese di pressione di valle e la
velocità del gas nel punto di presa rispettino i valori
indicati sulle tabelle 3 e 4 (posizionamento) e 5 (velo-
cità).
Allo scopo di evitare il raccogliersi di impurità e con-
dense nei tubi delle prese di pressione si consiglia:
a) che i tubi stessi siano sempre in discesa verso l’at-
tacco della tubazione di valle con una pendenza
all’incirca del 5-10%;
b) che gli attacchi della tubazione siano sempre salda-
ti sulla parte superiore della tubazione stessa e che
il foro sulla tubazione non presenti bave o sporgen-
ze verso l’interno.
NB.
NON INTERPORRE VALVOLE DI INTERCETTA-
ZIONE SULLE PRESE DI IMPULSO
Содержание DIVAL 160 AP
Страница 42: ...MANUALE TECNICO MT059 TECHNICAL MANUAL MT059 42 NOTE NOTES ...
Страница 44: ...July 2016 c ...