7.5.1 - STANDARD VERSION ADJUSTMENTS
In case it is necessary, for standard regulators with or without block valves, to change the setting values in order to in-
crease or decrease the operating pressure, proceed as shown in Tab.7.45:
Step Operation
Equipment required
1
Remove the top cap (A) of the regulator.
-
2
Turn the ring nut (B):
• clockwise to increase the downstream pressure;
• counterclockwise to decrease the downstream pressure.
Hexagonal wrench CH 11 mm
3
Replace the top cap (A) of the regulator.
-
Tab. 7.45.
A
B
Fig. 7.21. Operating pressure adjustment (Standard version)
Small calibration variations of ±10% from the value on the identification plate (see Section 2.8 "Identifica
-
tion plates applied") can be made only by observing the spring ranges in the tables in Chapter 10 ("Cali
-
bration tables").