![Pierce HUSKY 12 GPM Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/pierce/husky-12-gpm/husky-12-gpm_operation-and-maintenance-manual_1555697056.webp)
MAINTENANCE
4-22
/ Husky 12 Foam System
© 2017 Pierce Manufacturing Inc. All Rights Reserved.
11. Water flow reads 000 when
flowing water.
Wiring issue.
•
Check wiring. Unplug the
flowmeter and check for a good
ground, ckt# 1640. Check for
6-9 volt supply to flowmeter,
ckt# 2884.
Bad flowmeter
•
Check flowmeter. Remove
flowmeter and check for
obstructions or visible damage.
Manually spin the paddle wheel
and observe the display.
Display should indicate flow.
12. Water in hydraulic oil
Defective oil cooler.
•
Check for carry over in oil
cooler. If water is found in the
oil, change the oil.
Pressure washing near filler cap on
oil reservoir.
•
Use caution when pressure
washing around oil reservoir.
13. System will not pump foam from
foam tank.
•
See
Troubleshooting- System Will
Not Pump Foam from Foam
Tank”
Table
4-2:
Specialized
Troubleshooting-
System Will Not Pump Foam from Foam Tank
Question
Reason for Question
Test Procedure
A. Is there foam in the foam
tank?
The foam system will not
operate properly without
an adequate supply of
concentrate.
Visual inspection.
Table
4-1:
General Troubleshooting
Symptom
Possible Cause
Corrective Action
No
Yes
Содержание HUSKY 12 GPM
Страница 2: ......
Страница 6: ...TABLE OF CONTENTS iv Husky 12 Foam System 2017 Pierce Manufacturing Inc All Rights Reserved ...
Страница 8: ...FOREWORD vi Husky 12 Foam System 2017 Pierce Manufacturing Inc All Rights Reserved ...