The Sentinel Guard device can also be used to monitor the mains power supply. The device can be connected to the 
same mains socket as the compressor or pumping station. 

Should  there  be  a  power  outage,  the  device will  begin 

the  alarm  procedure

.  The  status  of  the  mains  power  supply  monitoring  can  be  seen  in  the  first  page  of  the  LCD 

screen. If the device is started without connecting the power connector, the screen will remain red and the power 
supply monitoring will be disabled. 

 

POWER FAILURE ALARM

 

The Sentinel Guard device can also be used to monitor water level. 

The device will come with one water sensor in-

cluded. 

The sensor can be connected to the water sensor socket, after which the W# indicator will be lit. If the indi-

cator is not lit even though the sensor is connected, the sensor might not be properly connected; reattach the sen-
sor. The sensor should be installed around 5 to 10 cm above the floating valve of the pump. 

The sensor should not 

be  installed  directly  below  the  inlet  pipe  of  the  pumping  station;  instead,  install  is  so  that  it  is  clear  of  major 
splashes.

 

Should the sensor be covered in water, the device will begin the alarm procedure. 

The sensor will most 

likely  get  dirty  during  usage,  and  it  can  be  cleaned  by  unscrewing  the  four  Phillips  screws  and  rubbing  the  circuit 
board found inside with rubbing alcohol. 

 

WATER SENSOR

 

By default, the Sentinel Guard is set to wait 2 minutes from the triggering of an alarm before sending alarm messa-
ges. 

The delay can be changed with the command 

Alarm xx

” 

where xx is the alarm delay in seconds. For example, 

the command 

Alarm 

30” 

would change the alarm delay to 30 seconds. 

 

CHANGING THE ALARM DELAY

 

The units of the pressure shown by the Sentinel Guard can be changed with a command. Changing the units to kPa 
can be done with the command 

Units kpa

”, 

and changing the units to PSI can be done with the command 

Units 

psi

”. 

 

CHANGING THE UNITS

 

The Sentinel Guard default settings can be changed when needed by SMS commands. Simply send a command mes-
sage  to the  device  number to alter any setting needed. Press Info Button to check from the  correct  page  that the 
setting has been changed as intended.   

 

Function

 

SMS Command Line

 

Adding Number

 

Add 0449587362

 

Deleting Number

 

Del 0449587362 or Del 2*

 

Changing the pressure limit 

 

L1 

45

—sets the low limit of sensor 1 to 45 kPa (0.45 bar)

 

H2 

65

—sets the high limit of sensor 2 to 65 kPa (0.65 bar)

 

Changing the alarm delay

 

Alarm 

30

—sets the delay to 30 seconds

 

Units psi—changes the units to psi

 

Changing the units 

 

Units kpa—changes the units to kPa

 

Pressure request

 

Pressure

 

*  2  is  the  index  number  you  want  to  delete.  The  index  number 
can be seen in the phone number page of the LCD screen.

 

Содержание Sentinel Guard

Страница 1: ...tructions are for your personal safety Always ensure that you have read and understood these instructions before using the machinery SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE We now have resellers in the U S Europe Australasia Locate your reseller at picotesolutions com ...

Страница 2: ...ARTS 11 WARRANTY POLICY PROCEDURE 12 To watch practical demonstration videos or to download an electronic copy of these In structions please visit www picotesolutions com Please note that videos are not intend ed as a replacement or alternative to this operating and safety manual but only as an additional learning tool TABLE OF CONTENTS ...

Страница 3: ...Safety symbols are used throughout this manual to draw attention to potential hazards Personal Protective Equipment PPE Always use Personal Protective Equipment which is needed on a working site where the Sentinel Guard 2 0 is being deployed Danger risk of serious injury follow instructions SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE ...

Страница 4: ...lutions This section contains important safety information Failure to comply could result in serious injury or death This section contains important safety information Failure to comply could result in serious injury or death TRANSPORT Sentinel Guard 2 0should be transported in car or other vehicle secured so that any sudden movements caused by hard braking or accident are prevented Always tranpor...

Страница 5: ... a built in remote alarm feature This allows it to send an alert message to a mobile phone in cases of power outage fluctuation of the pressure outside the limits or water level in a pumping station rise too high The alert messages are sent via the GSM network GENERAL INFORMATION INDICATORS SWITCHES Indicator Switch Function E When lit power supply monitoring is enabled W When lit water sensor mon...

Страница 6: ...After inserting the SIM card into the Sentinel put the T shaped cover back on top and gently fasten the screws It is recommended to use subscription based SIM cards and not prepaid SIM cards Prepaid SIM cards might run out of credit or be closed down inconspicuously CONNECTORS There are three different types of connectors in the Sentinel device pressure water and power The pressure con nectors and...

Страница 7: ... low and high limits of the pressure alarms The limits can be chosen individually for both sensors The limits work intuitively if the pressure drops below the low limit or raises above the high limit alert messages will be sent The default limits are 35 kPa 5 07 psi for low limit and 85 kPa 12 3 psi for high limit Pressure alarm limits can be changed at any time Look at the section Changing Parame...

Страница 8: ...D screen shows all the numbers in the SIM card memory The numbers are shown as a list and if more than 4 numbers have been added the page will scroll down for a new set of numbers GSM NUMBERS The Sentinel Guard device works in the GSM network Therefore it is imperative to have a GSM network signal The signal level can be seen in the details page of the LCD screen by pressing the INFO button Should...

Страница 9: ...ewing the four Phillips screws and rubbing the circuit board found inside with rubbing alcohol WATER SENSOR By default the Sentinel Guard is set to wait 2 minutes from the triggering of an alarm before sending alarm messa ges The delay can be changed with the command Alarm xx where xx is the alarm delay in seconds For example the command Alarm 30 would change the alarm delay to 30 seconds CHANGING...

Страница 10: ...essure sensor 2 high limit 1 0501111111 2 0502222222 3 0503333333 4 0504444444 The phone numbers saved in the SIM card memory are shown in the phone number page of the LCD screen The alarms will be sent to each of these numbers The maximum amount of numbers stored in the SIM card memory is 20 The numbers are listed as shown below MANAGING PHONE NUMBERS The numbers can be added and deleted with two...

Страница 11: ...se only the Picote Solutions accessories and attachments with the machine described in this operations manual The use of other accessories or attachments could present a risk of injury or death The accessories or attachments should only be used in the proper and intended manner and always follow Picote Solutions instructions ACCESSORIES SPARE PARTS 6100000020 Sentinel Liner Guard Type 1 EU 6100000...

Страница 12: ...rts accessories or third party products when using the Products or 6 the use of the Products not in compliance with their respective Documentation user manuals safety and maintenance instructions and any usage restrictions contained therein or 7 accident fire power failure power surge or other hazard Otherwise the Products are sold AS IS End User is responsible for using the Products within their ...

Страница 13: ...r or sales picotesolutions com 44 0 7585 116508 1 219 440 1404 Technical Support 1 706 436 1892 Manufacturer Picote Solutions Oy Ltd Raudoittajantie 4 06450 Porvoo Finland www picotesolutions com Revision Date 24 Oct 2019 Revision number Rev 1 Author Mikko Långvik Accepted ...

Отзывы: