1.  Description

The TA466 Two-pole voltage detector can be used for carrying out no-voltage checks, and for 

measuring up to 690 V AC and up to 950 V DC.

It is designed to be easily handled. The test probes are clipped to the underside of the casing for 

storage and for easy use on standard European outlets (centre-to-centre distance: 19 mm). 

The voltage detector has the following features: 

• ± polarity indicator

• Audible continuity indicator (< 100 Ω)
• Phase order indicator in a three-phase system (by the two-wire method)
It is fitted with IP65 safety test probes (by design) and a built-in correct operation testing system 

(self-test).

The voltage detector can be used for the following:

• Checks of AC and DC voltage levels 

or 

measurements of alternating voltages up to 690 V (50 and 

60 Hz) and direct voltages up to 950 V
• Phase detection (by the unipolar method)

2.  Appearance

Содержание TA466

Страница 1: ...User s guide TA466 Two pole voltage detector www picoauto com...

Страница 2: ...Battery level indicator 4 3 4 AC or DC voltage verification and measurement 4 3 5 Polarity check direct voltage 5 3 6 Phase neutral check alternating voltages 5 3 7 Phase order check three phase syst...

Страница 3: ...use on standard European outlets centre to centre distance 19 mm The voltage detector has the following features polarity indicator Audible continuity indicator 100 Phase order indicator in a three ph...

Страница 4: ...tative to arrange the return Note 2 The correct operation check function is there to make sure that the test leads battery and electronic circuit integrity are working and correct 3 3 Battery level in...

Страница 5: ...rmine the phase order in a three phase system You perform this operation in two sequences using the two test probes First make sure that there is voltage present and that it has the same value for eac...

Страница 6: ...test button 3 10 Battery replacement Make sure that the device is disconnected from all voltage sources The battery must be replaced when the correct operation check self test fails 1 Use a Pozidriv s...

Страница 7: ...bris and to recreate and or increase the insulation clean the device with a cloth coated with silicone MO984 Change the batteries Perform daily inspection Note For any non compliance during the period...

Страница 8: ...V AC 950 V DC Overvoltage protection CAT IV 600 V CAT III 1000 V relative to earth ground Indicators Audible alarm and light Display counts 1000 Input resistance 700 k at 50 V AC Frequency 50 60 Hz 3...

Отзывы: