background image

5

Unpacking

The positioner is delivered with the transport safeguard installed.

1

2

Figure 4: V-417.xx6025E0 with transport safeguard
1. Transport safeguard
2. Wing screw with M6×10 thread

CAUTION

Risk of crushing by moving parts!

Risk of minor injuries from crushing between the moving parts of the V-417.xx6025E0 or the
load and a fixed part or obstacle.

Transport the V-417.xx6025E0 only when the transport safeguard is attached.

Bring the V-417.xx6025E0 to the intended place of use. If the V-417.xx6025E0 was supplied
with a carrying aid: Use the carrying aid to transport the V-417.xx6025E0.

Remove the transport safeguard afterwards.

Unpack the V-417.xx6025E0 and remove the transport safeguard

1. Unpack the V-417.xx6025E0 with care.
2. Compare the contents with the scope of delivery according to the contract and the

delivery note.

3. Inspect the contents for signs of damage. If any parts are damaged or missing, contact

our 

customer service department (p. 24)

 immediately.

4. If the V-417.xx6025E0 was supplied with a carrying 

aid (p. 9)

: Use the carrying aid to

transport the V-417.xx6025E0 to the intended place of use.

5. If the V-417.xx6025E0 was supplied with ESD protective caps on the connectors: Do not

remove the ESD protective caps.

6. Remove the transport safeguard:

a) Unscrew and remove the wing screw.
b) Remove the transport safeguard.

7. Keep all packaging materials and the transport safeguard in case the product needs to be

returned.

5  UNPACKING

V417M0010EN 

 4/26/2019

12

M O T I O N   |   P O S I T I O N I N G

Содержание PIMAG V-417.056025E0

Страница 1: ...V417M0010EN 4 26 2019 User Manual V 417 XX6025E0 PIMAG HIGH LOAD LINEAR STAGE M O T I O N P O S I T I O N I N G...

Страница 2: ...Scope of Delivery 9 4 4 Overview 10 4 4 1 Base Body 10 4 4 2 Drive 10 4 4 3 Linear Encoder Connector 10 4 4 4 Purge Air System 10 4 5 Suitable Electronics 11 5 Unpacking 12 6 Installation 13 6 1 Moun...

Страница 3: ...cations 25 12 2 Maximum Ratings 27 12 3 Ambient Conditions and Classifications 27 12 4 Dimensions 28 13 Old Equipment Disposal 30 14 Appendix 31 14 1 Pin Assignment 31 14 1 1 Drive Connector 31 14 1 2...

Страница 4: ...are protected by copyright With regard thereto Physik Instrumente PI GmbH Co KG reserves all rights The use of any text images and drawings is permitted only in part and only when indicating the sourc...

Страница 5: ...duct example socket of the RS 232 interface Start Settings Menu path in the PC software example to open the menu the Start and Settings menus must be clicked successively POS Command line or a command...

Страница 6: ...ng the access data You need the data storage device for the product to get the access data If a manual is missing or problems occur with downloading contact our customer service department p 24 Downlo...

Страница 7: ...Instructions The V 417 xx6025E0 is built according to state of the art technology and recognized safety standards Improper use of the V 417 xx6025E0 may result in personal injury and or damage to the...

Страница 8: ...417 096025E0 204 mm 8 V 417 136025E0 305 mm 12 V 417 176025E0 407 mm 16 V 417 216025E0 508 mm 20 V 417 256025E0 610 mm 24 V 417 336025E0 813 mm 32 4 2 Product Labeling 1 2 1 3 2 6 7 5 4 Figure 1 Produ...

Страница 9: ...o the order p 8 For V 417 xx6025E0 with xx 05 09 13 17 V417B0015 Mounting kit for mounting the V 417 xx6025E0 consisting of 12 socket head screws ISO 4762 M6 30 2 dowel pins ISO 8734 4m6 12 12 flat wa...

Страница 10: ...the position Therefore no referencing is necessary when switching on The position is measured directly at the motion platform which minimizes the influence of mechanical play and deformation when mea...

Страница 11: ...h creates a slight overpressure in the V 417 xx6025E0 and therefore reduces the amount of dust that can penetrate 4 5 Suitable Electronics The V 417 xx6025E0 must be connected to suitable electronics...

Страница 12: ...x6025E0 and remove the transport safeguard 1 Unpack the V 417 xx6025E0 with care 2 Compare the contents with the scope of delivery according to the contract and the delivery note 3 Inspect the content...

Страница 13: ...uired to route cables without bending and according to regulations DANGER Risk of electric shock if the protective earth conductor is not connected If the protective earth conductor is missing or not...

Страница 14: ...rface 2 Align the V 417 xx6025E0 on underlying surface so that the corresponding mounting holes in the V 417 xx6025E0 and underlying surface in line 3 Put the V 417 xx6025E0 onto the underlying surfac...

Страница 15: ...n the event of malfunction or failure of the system If there are touch voltages touching the V 417 xx6025E0 leads to serious injuries or death by electric shock Connect the V 417 xx6025E0 to a protect...

Страница 16: ...locating pins that are inserted too deeply can damage the V 417 xx6025E0 Pay attention to the depth of the mounting and locating holes p 29 in the V 417 xx6025E0 Only use screws and locating pins of...

Страница 17: ...ly use screws and locating pins of the correct length for the respective mounting holes Fixing the Load 1 If necessary Insert the locating pins into the corresponding holes in the motion platform 2 Al...

Страница 18: ...tive caps from the connectors of the V 417 xx6025E0 2 All of the V 417 xx6025E0 s connections must be made in the following order a Optional Purge air connector Permissible pressure 2 to 6 bar 200 to...

Страница 19: ...hock Connect the V 417 xx6025E0 to a protective earth conductor before startup Do not remove the protective earth conductor during operation If the protective earth conductor has to be removed tempora...

Страница 20: ...ion is indicated by a humming noise and can result from the following causes The load and or dynamics during operation differ considerably to the calibration settings The V 417 xx6025E0 is operated ne...

Страница 21: ...p 24 NOTICE Damage due to unsuitable cleaning agents Some cleaning agents can cause rusting on the V 417 xx6025E0 or dissolve plastics paints or adhesives Do not clean with water or acetone Cleaning...

Страница 22: ...table due to inappropriately set speed acceleration Correct the corresponding servo control parame ter settings see the user manual for the control ler Uncontrolled oscillation Large changes to the lo...

Страница 23: ...cal load on the V 417 xx6025E0 due to transportation without a safeguard can damage the V 417 xx6025E0 and lead to loss of accuracy Ship the V 417 xx6025E0 in the original packaging only and with the...

Страница 24: ...of the controller if applicable Version of the driver or the software if applicable Operating system on the PC if applicable If possible Take photographs or make videos of your system that can be sen...

Страница 25: ...417 33 Unit Toler ance Active axes X X X Travel range 508 610 813 mm Pitch yaw 40 45 50 rad max Straightness flat ness 9 10 12 m max Velocity unloaded 2000 2000 2000 mm s max Positioning accura cy un...

Страница 26: ...Unit Toler ance Drive type Ironless 3 phase linear motor Intermediate circuit voltage RMS 300 V DC max Peak force 300 N typ Nominal force 87 N typ Peak current RMS 15 A typ Nominal current RMS 4 4 A t...

Страница 27: ...motor M17 linear encoder Fitting for purge air hose with outside diame ter 4 mm Purge air system Operating pressure 2 to 6 bar 200 to 600 kPa Relative humidity 70 Absolute humidity 35 g m3 Recommended...

Страница 28: ...2 4 Dimensions A D Energychain overlap at hardstop X B center of travel position reference position 6 6 10 8x6 4 15 1 2 LSW LE1 1 2 LSW LE2 1 2 HDS 1 2 HDS 150 C 150 4 x 4 H7x7 10 7 5 8 5 83 5 82 5 X...

Страница 29: ...platform of the V 417 xx6025E0 Dimensions and mounting holes Dimensions in mm Note that the decimal places are separated by a comma in the drawings 12 TECHNICAL DATA V417M0010EN 4 26 2019 29 M O T I O...

Страница 30: ...order to fulfil the responsibility as the product manufacturer PI miCos undertakes environmentally correct disposal of all PI miCos equipment free of charge if it was made available to the market afte...

Страница 31: ...PE Figure 11 M17 9 f Pin Function A Phase 1 B Phase 2 C Phase 3 1 Output Temperature sensor NTC 2 Output Temperature sensor NTC 3 Not connected 4 Not connected 5 Outer shielding PE Protective earth 1...

Страница 32: ...B Output Temperature sensor PTC C Outer shielding 14 2 NTC temperature sensor The V 417 xx6025E0 is equipped with an NTC temperature sensor for monitoring the coil temperature The electrical resistanc...

Страница 33: ...7 xx6025E0 electrical resistance over temperature 0 C to 80 C 0 200 400 600 800 1000 1200 1400 80 85 90 95 100 105 110 115 120 125 130 R T C Figure 14 NTC temperature sensor of the V 417 xx6025E0 elec...

Страница 34: ...to prevent the motor from overheating The electrical resistance of the PTC temperature sensor increases considerably into the critical temperature range The controller must cut the power supply to th...

Страница 35: ...ith the following European directives Low Voltage Directive EMC Directive RoHS Directive The standards applied for certifying conformity are listed below Safety Low Voltage Directive EN 61010 1 EMC EN...

Страница 36: ...direct measurement methods the resolution of the sensor system is specified Lateral Force Also lateral load capacity Maximum permissible force orthogonally to the positioning direction This value is v...

Страница 37: ...ge The maximum possible travel range is limited by the length of the drive screw A possible gap between the limit switches determines the travel range V417M0010EN 4 26 2019 37 M O T I O N P O S I T I...