background image

User Manual 

P726T0002, valid for P-726.1CD 

CBo, 10/18/2019 
 

 

Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany 

Page 3 / 17 

Phone +49 721 4846-0, Fax +49 721 4846-1019, Email 

[email protected]

, 

www.pi.ws

 

About this Document 

This manual contains information necessary for the intended use of the P-726.1CD. 
It assumes that the reader has a fundamental understanding of basic servo systems as well as 

motion control concepts and applicable safety procedures.  
The latest versions of the user manuals are available for download (p. 3) on our website. 

Symbols and Typographic Conventions 

The following symbols and typographic conventions are used in this user manual: 

 

CAUTION 

 

Dangerous situation 

If not avoided, the dangerous situation will result in minor injury. 

 

Actions to take to avoid the situation. 

 

 

NOTICE 

 

Dangerous situation 

If not avoided, the dangerous situation will result in damage to the equipment. 

 

Actions to take to avoid the situation. 

 

 

INFORMATION 

 

Information for easier handling, tricks, tips, etc. 

 

Downloading Manuals 

 

INFORMATION 

 

If a manual is missing or problems occur with downloading: 

 

Contact our customer service department (p. 12). 

  

 

INFORMATION 

 

For products that are supplied with software (CD in the scope of delivery), access to the 

manuals is protected by a password. Protected content is only displayed on the website after 

entering the access data. 
You need the product CD to get the access data. 

  

Содержание P-726.1CD

Страница 1: ...id for P 726 1CD CBo 10 18 2019 Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws P 726 1CD PIFOC Hig...

Страница 2: ...ed Use 5 Safety Precautions 5 Product Description 7 Product View 7 Scope of Delivery 8 Suitable Controllers 8 Accessories 8 Installation 9 Connecting the P 726 to a Protective Earth Conductor 9 Affixi...

Страница 3: ...symbols and typographic conventions are used in this user manual CAUTION Dangerous situation If not avoided the dangerous situation will result in minor injury Actions to take to avoid the situation...

Страница 4: ...c Click Show login data in the browser window d Note the user name and password shown in the browser window Downloading manuals If you have requested access data for protected contents via a registra...

Страница 5: ...system the controller must also be able to read out and process the signals from the position sensors The controller is not included in the scope of delivery of the P 726 Safety Precautions CAUTION D...

Страница 6: ...bles can damage the electronics Only use cables from PI for connecting the P 726 to the electronics NOTICE Destruction of the piezo actuator by electric flashovers The use of the P 726 in environments...

Страница 7: ...he following causes The load and or dynamics of operation differ too much from the calibration settings The P 726 is operated near its resonant frequency If you notice oscillations stop the P 726 imme...

Страница 8: ...Digital piezo controller E 709 Digital piezo controller E 625 Piezo servo controller E 665 Piezo amplifier servo controller E 500 Modular piezo controller system with E 505 high power amplifier modul...

Страница 9: ...nect the P 726 to a protective earth conductor 1 Make sure that the contact resistance is 0 1 at 25 A at all connection points relevant for mounting the protective earth conductor 2 Observe the applic...

Страница 10: ...r below the aperture Requirements You have read and understood the safety precautions p 5 Tools and accessories P726T0001 technical note for QuickLock thread option for P 726 p 8 QuickLock thread adap...

Страница 11: ...oller In open loop operation Set the piezo voltage to 0 V on the controller Discharging a P 726 that is not connected to the controller Connect the P 726 to the switched off PI controller for 10 secon...

Страница 12: ...f your system that can be sent to our customer service department if requested The latest versions of the user manuals are available for download on our website www pi ws Technical Data Specifications...

Страница 13: ...ifier and the measuring technology because PI piezo nanopositioning systems are free of friction All specifications based on room temperature 22 C 3 C Ask about customized versions Maximum Ratings P 7...

Страница 14: ...ions and Classifications Area of application For indoor use only Maximum altitude 2000 m Air pressure 1100 hPa to 1013 hPa Relative humidity Highest relative humidity 80 for temperatures up to 31 C De...

Страница 15: ...CBo 10 18 2019 Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Page 15 17 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi ws www pi ws Dimensions Dimensions in...

Страница 16: ...sub 7W2 m connector front view Pin Signal Function A1 inner conductor Input Piezo voltage A2 inner conductor Output Probe sensor signal nonmoving part of the capacitive sensor A2 outer conductor GND...

Страница 17: ...member states via the municipal residual waste Dispose of your old equipment according to international national and local rules and regulations In order to fulfil its responsibility as the product m...