5 Installation
M-230 Linear Actuators
MP102E
Version: 1.2
15
5.1 General Notes on Installation
NOTICE
Cable break!
A cable break leads to a failure of the linear actuator.
Install the linear actuator so that the cable is not bent or squeezed too severely
during operation.
NOTICE
Increased friction!
Lateral forces that affect the pusher of the linear actuator increase the friction on the
internal drive components. Increased friction impairs the motion of the pusher and
increases wear on the drive components.
Avoid lateral forces on the tip and on the pusher of the M-230.
NOTICE
Heating up of the M-230 during operation!
The heat produced during operation of the M-230 can affect your application.
Install the M-230 so that your application is not affected by the dissipating heat.
INFORMATION
Models with DC gear motors are equipped with integrated signal drivers for cable
lengths
≤
10 m between the linear actuator and the motor controller.
5