10 Technical Data
L-406 Compact Linear Stage
MP150E
Version: 1.1.0
45
Miscellaneous
L-406.x0DD10
L-406.x0DG10
L-406.x0SD00
Unit
Tole-
rance
ACS modular
controller
ACS modular
controller
663.12C885 (up to
20 axes)
ACS modular
controller
10.1.2
Maximum Ratings
The L-406 positioners are designed for the following operating data:
Product
Maximum operating
voltage
Operating frequency Maximum power
consumption
L-406.x0DG10
12 V
0 Hz
8.5 W
L-406.x0DD10
24 V
0 Hz
21 W
L-406.x0SD00
24 V
0 Hz
10.8 W
10.1.3
Ambient Conditions and Classifications
The following ambient conditions and classifications for the L-406 must be observed:
Area of application
For indoor use only
Maximum altitude
2000 m
Relative humidity
Max. 80 % for temperatures up to 31 °C
Linearly decreasing to 50 % at 40 °C
Storage temperature
0 °C to 80 °C
Transport temperature
0 °C to 80 °C
Supply fluctuations
Max. ±10 % of the nominal voltage
Degree of pollution
2
Degree of protection
according to IEC 60529
IP40