User Manual
L306T0002, applies to L-306.011100 / 011112 / 013112
MMa, 2019-AUG-20
PI miCos GmbH, Freiburger Strasse 30, 79427 Eschbach, Germany
Page 7 / 25
Phone +49 7634 5057-0, Fax +49 7634 5057-99, Email
Mechanical Installation
General Notes on Installation
NOTICE
Electrostatic hazard
Touching the pins in the connections of the positioner can damage electrostatic sensitive
devices (ESD) of the positioner. Also for this reason, the positioner is supplied with a
protection cap on the connector.
Do
not
remove the protection cap from the connector until you connect the positioner
to the controller.
NOTICE
Cable break!
A cable break leads to failure of the positioner.
Install the positioner so that the cable is not bent too strongly or crushed.
NOTICE
Heating of the positioner during operation!
The heat produced during operation of the positioner can affect your application.
Install the positioners that the application is not impaired by the dissipated heat.
Avoid excess of the allowed max. velocity (5 mm/s). Operation within the allowed
velocity range is automatically ensured by correct selection/detection of the product
model in the motion control software.
INFORMATION
For optimal repeatability, all components must be connected firmly together.
INFORMATION
The use of locating pins during mounting reduces deviations from the ideal alignment of the
positioner.
If possible, simulate the positioner motion with a mounted load or make suitable
calculations to detect collisions or unfavorable center of gravity constellations.
If necessary, take suitable constructive measures to avoid collisions and instability in
the overall system.