10 Technical Data
L-220 Linear Actuator
MP149E
Version: 1.3
31
10.1.3
Ambient Conditions and Classifications
The following ambient conditions and classifications must be observed for the L-220:
Area of application
For indoor use only
Maximum altitude
2000 m
Relative humidity
Max. 80 % for temperatures up to 31 °C
Linearly decreasing to 50 % at 40 °C
Storage temperature
-25 °C to 85 °C
Transport temperature
-25 °C to 85 °C
Supply fluctuations
Max. ±10 % of the nominal voltage
Degree of pollution
2
Degree of protection according to IEC 60529 IP040
10.1.4
Limit Switch Specifications
Type
Magnetic (Hall effect) sensor
Supply voltage
+5 V / ground
Signal output
Open collector (wiring 5 V to 24 V / max. 50 mA)
Signal logic
The signal level changes when passing the limit switch. The signal logic
is active high. That means:
Proper operation of the motor: Collector switches through.
Limit switch reached: Collector blocks
10.1.5
Reference Point Switch Specifications
Type
Magnetic (Hall effect) sensor
Supply voltage
+5 V / GND
Signal output
Open collector (wiring 5 V to 24 V / max. 50 mA)
Signal logic
Blocking or switching through of the collector after passing the
reference point switch, depending on the direction.